background image

THE KEY TO SALON SUCCESS

PRIVE PEDICURE SPA USER MANUAL

RECEIVING AND INSPECTION: If missing parts or damages are found, please notify the carrier at once and
insist on a notation of the damage on the bill of lading. DO NOT DISCARD THE SHIPPING BOX. If you give
the carrier a clear receipt for goods that have been damaged in transit, you do so at your own risk and
expense.

Table of Contents

Identifying Parts for PRIVE® Model

1

WALL CLEARANCE  & SPA to SPA RECOMMENDED CLEARANCE

2

INSTALLATION OF PEDICURE SPA DOME

2

INSTALLATION OF PEDICURE SPA SEAT

3

INSTALLATION OF PLUMBING SYSTEM

5

INSTALLATION OF VENTILATION SYSTEM (OPTIONAL)

8

ELECTRICAL AND PEDICURE SPA COMPONENT SPECIFICATIONS

9

PRE-OPERATIONAL SETUP

10

OPERATE Auto-Fill™/Jet Switch:

12

OPERATE DIGITAL CONTROL PANEL:

13

RESET WATER SENSOR AND WATER LEVEL

14

MASSAGE SYSTEM & REMOTE CONTROLLER

16

WARNING:

1.This Product is for indoor use only & is not recommended for use on Carpet or Wood floor

2. This Product must be connected to a circuit outlet protected by a Class A GFCI
3. DO NOT USE if you have poor circulation, or if any area of your feet or legs has an open sore
4. Maximum temperature of the water should never exceed 100 degrees F.
5. DO NOT STEP/ STAND IN THE FOOT BASIN.
6. NEVER bring and/or operate any electrical devices in or near the Pedicure Spa.
7. Maximum load in the spa chair is 250lbs (114kg).

PROPER INSTALLATION ACCORDING TO THIS MANUAL IS REQUIRED. FAILURE TO DO SO MAY RESULT IN

SERIOUS INJURY AND/OR WARRANTY WILL BE NULL. YOU MUST HAVE A LICENSED PLUMBER TO CONNECT THE

SPA AND WATER SYSTEM IN PLACE SAFELY.

STATES’ NOTICE

In the commonwealth of most states, all pedicure spas installed for Commercial usage are required to have a
backflow preventer at the salon’s cost. This device shall be installed between the water inlet hose and the
spout.

PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

Содержание PRIVE

Страница 1: ...TE CONTROLLER 16 WARNING 1 This Product is for indoor use only is not recommended for use on Carpet or Wood floor 2 This Product must be connected to a circuit outlet protected by a Class A GFCI 3 DO...

Страница 2: ...Identifying Parts for PRIVE Model Pedicure Spa with Massage System 1...

Страница 3: ...e to wall 0 5inches 1 25cm and base to wall 10 inches 25 4cm are mandatory to give enough space for the unobstructed chair recline and plumbing system connections Failure to follow may result in serio...

Страница 4: ...INSTALLATION OF PEDICURE SPA SEAT 1 FOLD UNFOLD BACK REST MASSAGE 2 ASSEMBLE THE BACK AND SEAT CUSHION 3...

Страница 5: ...3 ASSEMBLE THE ARM RESTS Complete 4...

Страница 6: ...ith SECTION 701 0 2018 UPC 2 Trap vent and connectors should comply with SECTION 1001 1 and 1001 2 UPC 3 An alternative code needs to be complied with by the states not adopting UPC a Drainage system...

Страница 7: ...e complied with by the states not adopting UPC a Drainage system SECTION 701 2 and 702 2 IPC or local plumbing code b Trap vent and connectors SECTION 1002 1 and 1002 2 IPC or local plumbing code 4 Th...

Страница 8: ...be carefully compiled to pass the city inspections New constructions drain a good amount of water in a bucket to remove all debris from the new hot cold water pipes before connecting to new SPA chair...

Страница 9: ...ON OF VENTILATION SYSTEM OPTIONAL The Spa comes with a preinstalled ventilation system because it is required by some state regulation Please contact your state department for the requirements and reg...

Страница 10: ...g 120V AC Max 850W for first 2 mins 400W constant Adjustable Stool Pedicure Stool Manicure Stool 12 13 16 25 20 Spa Water Capacity 4 US Gallon Jet Motor 120 VAC At 85W 60Hz Massage Motors Seat Sliding...

Страница 11: ...PRE OPERATIONAL SETUP 1 SETUP THE STEAMER 2 SETUP THE Eco Jet 10...

Страница 12: ...cture above before each service section Note to assure the safety of the operator if the silicon pipe is not connected or accidentally popped out from the connector the safety device will shut off the...

Страница 13: ...drain knob clockwise to start draining Twist it back when the draining is done Use Hot Cold water knob to manually adjust the water temperature To shut off the main water valve follow the instruction...

Страница 14: ...rrent working status Eco Jet action can cause small amounts of soap or body oil to foam excessively For this reason refrain from using these products during the whirlpool cycle For safety reasons the...

Страница 15: ...d be pressed slowly Press and hold the SteamHeat Button for 3 sec to resume system operation or the system will be automatically resumed if no action is taken in 20 sec 2 Adjust The Water Level For Au...

Страница 16: ...he Steamer Timeout turn off all system functions for configuration 4 Reset to The Factory Setting Factory Default Parameters Water level 3 Steamer Timeout 20 mins Safety device Enabled Unit of tempera...

Страница 17: ...mbine to enter Manual mode 3 Press Rolling Spot to stop rolling up down and stop at the desired spot 4 Press the Intensity button to select tapping intensity 5 A Warmer Button is an option Pressing th...

Страница 18: ...ap or detergent and water 3 The spa basin must be disinfected with an EPA registered disinfectant with demonstrated bactericidal fungicidal and virucidal activity which must be used according to the m...

Страница 19: ...s Chinese New Year s and Independence Day are not available Shipping Damages Shipping damages must be claimed within 48 hrs after receiving the products An investigation by the carrier can take up to...