background image

Содержание PRIVE LOUNGE

Страница 1: ......

Страница 2: ...NT 20 STEAMERS REPLACEMENT 21 AF CONTROL BOX REPLACEMENT 22 WARNING 1 This Product is for indoor use only is not recommended for use on Carpet or Wood floor 2 This Product must be connected to a circu...

Страница 3: ...mated System Control Panel Optional 10 Sani DrainTM System with discharge On Off Knob 11 Hot Cold Water Mixer Valve 12 Dual Function Auto FillTM Jet On Off Knob 13 Aurora Bowl 14 Handbag Purse Hook 15...

Страница 4: ...l clearance for dome to wall 0 5inches 1 25cm and base to wall 10 inches 25 4cm are mandatory to give enough space for the unobstructed chair recline and plumbing system connections Failure to follow...

Страница 5: ...secure 2 M8 x 100 bolts attached near the mounting hole Re install the panel Locate and connect both ends of LED light power cables UPPER DOME ASSEMBLY Step 2 Open the panel labeled Upper Dome Install...

Страница 6: ...INSTALLATION OF PEDICURE SPA SEAT 5 1 FOLD UNFOLD BACK REST MASSAGE CLICK...

Страница 7: ...ecure 3 SEAT CUSHION ASSEMBLY Install the seat cushion by engaging the 2 rear hooks of seat cushion onto the seat frame Position the seat cushion then snap the fit joint of seat cushion to the seat fr...

Страница 8: ...female connectors labeled 1 between Right Armrest and Spa Base Armrests Removal Disconnect 8 pin cable connector of right armrest labeled 1 Vertically rotate left armrest clockwise counterclockwise wi...

Страница 9: ...with SECTION 701 0 2018 UPC 2 Trap vent and connectors should comply with SECTION 1001 1 and 1001 2 UPC 3 An alternative code needs to be complied with by the states not adopting UPC a Drainage syste...

Страница 10: ...be complied with by the states not adopting UPC a Drainage system SECTION 701 2 and 702 2 IPC or local plumbing code b Trap vent and connectors SECTION 1002 1 and 1002 2 IPC or local plumbing code 4...

Страница 11: ...pass the city inspections New constructions drain a good amount of water in a bucket to remove all debris from the new hot cold water pipes before connecting to new SPA chairs figure 1 Replacement Spa...

Страница 12: ...N OF VENTILATION SYSTEM OPTIONAL 11 The Spa comes with a preinstalled ventilation system because it is required by some state regulation Please contact your state department for the requirements and r...

Страница 13: ...ting 120V AC Max 850W for first 2 mins 400W constant Adjustable Stool Pedicure Stool Manicure Stool 12 13 16 25 20 Spa Water Capacity 4 US Gallon Jet Motor 120 VAC At 85W 60Hz Massage Motors Seat Slid...

Страница 14: ...rainage 1 Not Using the Drain Stopper The Air ring Stand should face down Press down the Air ring to lock it into the Drain shoe 2 Using the Drain Stopper Air ring stand should face up Press down Air...

Страница 15: ...each service session Note To assure the safety for the operator if the silicon pipe is not connected or accidentally popped out from the safety connector The safety device will shut off the steam syst...

Страница 16: ...to Fill Jet switch clockwise again Twist drain knob clockwise to start draining Twist it back when the draining is done Use Hot Cold water knob to manually adjust the water temperature Push button on...

Страница 17: ...ut the Steamer The Blue White LED light indicates the current working status Eco Jet action can cause small amounts of soap or body oil to foam excessively For this reason refrain from using these pro...

Страница 18: ...ould be pressed slowly Press and hold the SteamHeat Button for 3 sec to resume system operation or the system will be automatically resumed if no action is taken in 20 sec 2 Adjust The Water Level For...

Страница 19: ...t The Steamer Timeout turn off all system functions for configuration 4 Reset to The Factory Setting Factory Default Parameters Water level 3 Steamer Timeout 20 mins Safety device Enabled Unit of temp...

Страница 20: ...Rolling Spot to stop rolling up down and stop at the desired spot 4 Press the Intensity button to select tapping intensity 5 A Warmer Button is an option Pressing this button will start the heated se...

Страница 21: ...MENT Remove the 2 mounting screws on both sides of the top dome cover Disconnect LED cable connector as needed Remove the LED by lifting the springs holder and push down the LED housing Reverse the ab...

Страница 22: ...2 REPLACE THE STEAMER Remove Y Air Connector by using Pliers to lose the metal ring then remove the connector Turn the Steamer counter clockwise turn then lift to remove 1 Press down the latching lock...

Страница 23: ...e the side panel by lift the panel out of the holder then pull out the panel 2 REPLACE AF CONTROL BOX Remove all the connectors on the front of AF Control Box Push up and pull AF Control Box out of th...

Страница 24: ...r Pump BLACK Power socket Steamer Out WHITE Power socket Air Pump BLACK Power socket Whirlpool BLACK Power socket Drain Pump BLUE DC Power Plug 6 Pin Plug 10 Pin Plug 4 Pin Plug Cable Steamer in Power...

Страница 25: ...detergent and water 3 The spa basin must be disinfected with an EPA registered disinfectant with demonstrated bactericidal fungicidal and virucidal activity which must be used according to the manufa...

Страница 26: ...ranty Replacement parts are supplied with instructions and specially designed for simple installation therefore do not require a technician onsite SHIPPING DAMAGE CLAIM Shipping damages must be report...

Страница 27: ......

Страница 28: ......

Отзывы: