Lexing LX-SO-738-1 Скачать руководство пользователя страница 5

Wired network(use I/O port)

If the smoke detector is intended to be used in the "Wired network" mode, all the smoke detectors are 
necessary  to  interconnect  (see  wiring  diagrams)  by  the  18AWG  two  conductor  cables  (conductor 
cross-section 0.8m 

) connected to I/O port.

For this purpose there is necessary to drill the hole of needed diameter through the base in a place marked 
on the middle diagram and close the smoke detector into the base.

After the above mentioned base modification and the conductors installation is necessary to check, if the 
smoke detector is possible to close without problems into the base, it means without visible gap between 
the smoke detector and its base alongside all the smoke detector periphery.
Use the same method to connect the next smoke detector.

I

O

max 20pcs

•The alarm could be caused by a nuisance situation. Cooking smoke or a dusty furnace, sometimes called 

“friendly fires” can cause the alarm to sound. If this happens, open a window or fan the air to remove the smoke 

or dust. The alarm will turn off as soon as the air is completely clear. 
•If the alarm horn begins to beep every 35sec, this signal means that the detector’s battery is weak. Replace 

new battery immediately. Keep fresh batteries on hand for this purpose.  

Taking care of your smoke detector

To  keep  your  detector  in  good  working  order,  you  must  test  the  detector  weekly,  as  referring  to  section 
“TESTING YOUR SMOKE DETECTOR”.  
•Replace the detector battery once a year or immediately when the low battery “beep” signal sounds once 
every 35sec. The low battery “beep” should last at least 30 days. 

NOTE:For  replacement  battery  ,  use  Eveready  #522,  #1222,  #216;  Duracell  #MN1604;  or  Gold  Peak 
#1604P, #1604S; or Ultralife U9VL-J. 

•Open the cover and vacuum the dust off the detector’s sensing chamber at least once a year. This can be 
done when you open the detector to change the battery. Remove battery before cleaning. To clean detector, 
use soft brush attachment to your vacuum. Carefully remove any dust on detector components, especially on 
the openings of the sensing chamber. Replace battery after cleaning. Test detector to make sure battery is 
incorrectly. Check to make sure there is no obstruction inside the test button. If there is any dust in the test 

button, insert a toothpick from the back to the front. 

•Clean detector cover when it gets dirty. First open the cover and remove battery. Hand-wash cover with cloth 
dampened  with  clean  water.  Dry  it  with  lint-free  cloth.  Do  not  get  any  water  on  the  detector  components. 
Replace the battery, and close cover. Test detector to make sure that battery works correctly. ˙ Replace the 
detector once every 3 years recommendation. 

ATTENTION:when the product is switched on for the first time you should do this in clean 
air.When you need to replace the battery, you should wait a minute in the clear air before 
proceeding to install the new battery after you have removed the old battery. 