S3
S4 S5
Time setting
0
0
0
30min
±
3min
15min
±
2min
3min
±
1min
12sec
±
3sec
0
0
1
0
1
0
1
0
0
S1
S2
Detection range
0
0
2m
0
1
5m
1
0
10m
Detection range setting (sensitivity)
Time setting
Detection range is the term used to describe the radii of the more or less circular detection zone produced on
the ground after mounting the sensor light at a height of 2.5m, pull switch to the ON position as "1", pull switch
to the OFF position as "0”, switch location and detection range of the corresponding table is as follows:
NOTE: the above detection range is gained in the case of a person who is between
1.6m~1.7m tall with middle figure and moves at a speed of 1.0~1.5m/sec. if person’s stature,
figure and moving speed change, the detection distance will also change.
NOTE: after the light switches OFF, it takes approx. 1sec before it is able to start detecting
movement again. The light will only switch on in response to movement once this period
has elapsed.
The light can be set to stay ON for any period of time between 12±3sec and a maximum of 30±3min. Any
movement detected before this time elapse will re-start the timer. It is recommended to select the shortest time
for adjusting the detection zone and for performing the walk test.
Pull switch to the ON position as "1", pull switch to the OFF position as "0”, switch location and time setting of
the corresponding table is as follows:
SENS:S1,S2
TIME:S3,S4,S5
S6
S7
S8 Light-control
0
0
0
10LUX
0
0
1
100LUX
0
1
0
500LUX
1
0
0
2000LUX
Light-control setting
The chosen light response threshold can be infinitely from approx. 10-2000LUX, pull switch to the ON position
as "1", pull switch to the OFF position as "0”, switch location and light-control of the corresponding table is as
follows:
LUX:S6,S7,S8
S1
S2
ATTENTION:When use this product, please adjust the sensitivity to an appropriate position
you need, please do not adjust the sensitivity to maximum, to avoid the product does not
work normally caused by wrong motion.Because the sensitivity is too high easily detect the
wrong motion by wind blowing leaves & curtains, small animals, and the wrong motion by
interference of power grid & electrical equipment. All those lead the product does not work
normally !
When the product does not work normally, please try to lower the sensitivity appropriately,
and then test it.
1
0
1
0
1
0