3-13
Controlling the LXP-15
Owner's Manual Addendum
4.
Press SETUP to enter Setup Select Mode.
5.
Use the leftmost slider, the SETUP button, or the keypad to select the
desired setup.
Pressing
✱
on the keypad switches the display between “SETUP#” and
“EXTRN#”. While “SETUP#” is displayed, you can use the keypad to
select any internal setup (1–16). While “EXTRN#” is displayed, you can
use the keypad to select any external setup (1–128).
6.
Press ENTER to load the setup into the MRC and LXP-15.
Communication Problems
If the MRC is unable to communicate with the LXP-15, it will display one of
two error messages: “No Target,” or “SYNCH TIMEOUT.” The “No Target”
message is displayed if the MRC cannot “find” the LXP-15. This can occur
if the LXP-15 is not connected properly or if it is set to a different MIDI channel
than the MRC. To recover from a “No Target” error, it is necessary to re-
establish communication with the LXP-15. To do this, repeat the procedure
in
Establishing Two-way Communication.
The “SYNCH TIMEOUT” message is displayed if MIDI MERGE for the IN/
OUT ports connected to the LXP-15 is set to “ON,” or when MIDI data is
received faster than it can be processed by the MRC. To recover from a
“SYNCH TIMEOUT” error, simply press ENTER (and confirm that MIDI
MERGE is set to “OFF”).
Viewing and Editing LXP-15 Setup Parameters
LXP-15 setup parameters are viewed and edited on six MRC display
pages.
Pages can be selected by pressing PAGE repeatedly, or by pressing the
desired page number on the keypad.
To edit LXP-15 parameters from the MRC, simply select the desired page
and move the slider of the parameter you want to edit. The new value is
displayed on the MRC and transmitted to the LXP-15. (You can see the
parameter changes on the LXP-15 when MRC sliders are moved, if the LXP-
15’s “Update” parameter is set to “ON”, PAGE is turned to the appropriate
parameter page, and VIEW is pressed to display the parameter values.)