Lexicon Studio Setup Guide
5
The Lexicon Studio LDI-12T must now be set up to receive the wordclock transmitted by the
328. Open the Lexicon Studio Control Panel, by double clciking the Lexicon Studio icon in the
taskbar. and select ‘Clock Source’ from the page options.
Click on the drop down menu and select WCBNC as the clock source input.
If you do not have a wordclock cable connected,
the Lexicon Studio LDI-12T must slave to
the clock on one of its ADAT or S/PDIF inputs. Set the Lexicon Studio LDI-12T to use the clock
source from the ADATDATA 12T input or the SPDIF 12T Input as required using the method
described above.
If the wordclock cable is available,
the Lexicon Studio LDI-12T should slave to the clock on
the BNC wordclock input.
Lexicon Studio LDI-12T
Lexicon Studio LDI-12T
Lexicon Studio LDI-12T
Lexicon Studio LDI-12T
3
Wordclock
Wordclock
Wordclock
Wordclock