Maintenance

The 6KW, 12KW and 24KW portable dimmers are designed to be low maintenance; however, several precautionary steps will 

prolong the life of the electronic components. Whenever possible, limit the unit’s exposure to high ambient temperatures. Take 

care not to drop the device and always protect the controls and connectors from damage. Do not allow liquid of any kind to enter 

the unit.

All screws and connections should be checked, and tightened if necessary, on a regular basis, especially in rental and location 

applications. If the unit accumulates dust, disconnect it from power and clean it using compressed air. Always disconnect dimmer 

from power before performing any maintenance operation. 

Troubleshooting

If the portable dimmer does not operate as expected, check the power source and check all cables and connectors. Be sure the 

Mains Power circuit breaker is on. Confirm that the controlled load operates from a constant power 

 

supply and confirm that any remote console is sending valid DMX512-A data.

Control indicators do not illuminate:

 Confirm that power is present to the unit.

Inc and Dec buttons do not raise and lower the lighting level:

 Make sure the dimmer is in Manual mode 

 

(press and hold Function button until Manual LED illuminates).

Unit does not respond to remote DMX512 input:

 Check all control cabling and check that DMX Data LED is 

 

illuminated to indicate presence of control signal. Make sure that dimmer is in DMX or Relay mode (press and hold Function 

button until one of these LEDs illuminates).

Connected load switches on and off instead of dimming:

 Confirm that Relay mode is activated. Press and hold Function 

button until Relay LED illuminates. If a DMX512 address is displayed, Relay function is active. To deactivate Relay function, press 

Dec pushbutton. Display should go blank to indicate a return to dimming operation.

The dimmer does not respond to the user controls – Inc, Function, Dec:

 Reset the electronics by pressing the Reset 

button on the rear of the unit.

Connected load is ghosting and will not shut off:

 A pre-heat level has been set and is retained in memory. 

Cycle the Function button until the pre-heat LED illuminates and use the Dec button to reset the pre-heat level to zero. Use the 

 

Function button to return to Manual or DMX mode.

Load is stuck on and does not dim or switch off:

 Check to see if Relay mode is activated and the relay has been turned 

on manually. Press and hold Function button until Relay LED illuminates. If the display shows “ON” the relay has been turned on 

manually. Press the Dec button to turn the relay OFF. If the load remains on, the power device may have failed. Contact Technical 

Services at 1.855.LEX.1002

Technical Support

The staff at Lex Products is willing and available to help in any way possible. If you have questions or need 

 

technical advice or suggestions regarding this product, please contact Lex at 1.855.LEX.1002 or e-mail Lex at 

 

[email protected].

 Business hours are Monday through Friday, 8:30 am – 5 pm. In addition, Technical Services 

is available 24/7 via phone.

LEX User Guide

6

6KW

, 12KW and 24KW Por

table Dimmers

Содержание 6KW

Страница 1: ...r Guide REV009 www lexproducts com info lexproducts com 800 643 4460 Lex Products Corporation 15 Progress Drive Shelton CT 06484 203 363 3738 203 363 3742 Fax Lex West 11847 Sheldon Street Sun Valley...

Страница 2: ...l Resources 7 Extra Notes 7 This user guide is furnished exclusively to support installation and operation of the Lex 6KW 12KW and 24KW portable dimmers All concepts and ideas are the sole property of...

Страница 3: ...iability 8 bit resolution allows full 256 step dimming control to ensure exact level repeatability Circuit breaker protected Voltage regulation maintains dimmer output within 2 despite fluctuations in...

Страница 4: ...08VAC 60Hz power source may be used When the power connections are secure the dimmer may be energized by turning on the Mains Power breaker Should the breaker trip check the power source and cables be...

Страница 5: ...the input connectors Relay The relay mode allows the user to switch any 120VAC FD1 6K and FD1 12K or 240VAC FD1 24K fixture or device up to the capacity of the unit on and off The relay function may b...

Страница 6: ...is in DMX or Relay mode press and hold Function button until one of these LEDs illuminates Connected load switches on and off instead of dimming Confirm that Relay mode is activated Press and hold Fu...

Страница 7: ...hnology USITT DMX512 A Asynchronous Serial Digital Data Transmission Standard for Controlling Lighting Equipment and Accessories visit the following sites ANSI American National Standards Institute ww...

Страница 8: ...www LexProducts com info LexProducts com 8 Lex Products Corporation 15 Progress Drive Shelton CT 06484 203 363 3738 203 363 3742 Fax Lex West 11847 Sheldon Street Sun Valley CA 91352 818 768 4474 818...

Отзывы: