06

High-pass filter indications 

·

The currently active high-pass setting is illuminated.

Setting a high-pass filter

·

High-pass filters can be set by briefly pressing the high-pass filter push button 

. Settings are: Off, 

      

12 dB / octave at 40 Hz and 6 dB / octave at 150 and 300 Hz. High-pass filters eliminate unwanted 

      

low frequency noise such as structure borne noise.

Automatic attenuation function

The microphone will automatically adjust to the next higher attenuation level if it experiences clipping due to a 
high  SPL. The  microphone  enters  and  leaves  the  automatic  attenuation  mode  by  constantly  pressing  the 
attenuation push button 

 for more than 2 seconds. The microphone is set to automatic attenuation mode if 

the status indicator 

 is illuminated in red. Please note that the microphone will need 1/2 second to adjust to 

the new attenuation level.

 

LCT 640

Using the mic

Содержание LCT 640

Страница 1: ...www lewitt audio com EMPHASIZE THE IN YOUR GENUINE SOUND LCT 640...

Страница 2: ...r friendliness in both professional studio recording and onstage use The microphones of the LCT Authentica Series stand for unaltered sound and innovative features llluminated Settings Noiseless Push...

Страница 3: ...lead and background vocals drums percussion instruments grand pianos brass and woodwinds classical music ensembles In addition to the standard omni directional cardioid and figure 8 polar patterns the...

Страница 4: ...r interface for quick and easy handling even in dark environments Noiseless pushbuttons for quick and easy attenuation and HPF selection Clipping history automatic attenuation and key lock provide err...

Страница 5: ...dicator is illuminated in red The microphone indicates the clipping history if the status indicator flashes red and white in an alternating sequence Polar pattern indications The currently active pola...

Страница 6: ...h as structure borne noise Automatic attenuation function The microphone will automatically adjustto the nexthigher attenuation level if itexperiences clipping due to a high SPL The microphone enters...

Страница 7: ...ng sequence the polar pattern indications as well as the high pass indications are not illuminated Clipping history mode provides information and works according to the rules listed below The last man...

Страница 8: ...Tech data Tech graph Dimensions 52 158 Broad cardioid 3 dB unit dB 1V Pa ref Cardoid 3 dB unit dB 1V Pa ref Figure 8 3 dB unit dB ref 1V Pa Super cardioid 3 dB unit dB 1V Pa ref Omni 3 dB unit dB 1V P...

Страница 9: ...A omni IEC 61672 1 13 dB A figure 8 IEC 61672 1 Dynamic range of mic amp Max SPL for 0 5 THD Pre attenuation pad Bass cut filter slope Rated impedance Rated load impedance Supply voltage Current cons...

Страница 10: ...Accessories LCT 640 LCT 40 x W AIu case LCT 40 SHx DTP 40 Lb Accessories 10...

Страница 11: ...fied service personnel in case any service is needed Please do not disassemble or modify the microphone for any reasons as this will void users warranty The casing of the microphone can be cleaned eas...

Страница 12: ...pliance Any defective parts removed from a product during the course of a warranty claim shall become the property of LEWITTGmbH While under warranty period defective products may be returned to the a...

Страница 13: ...GmbH hereby declares under its sole responsibility that LCT 640 has been tested and conforms to the following FCC and ANSI standards FCC Part 15 2008 Section 15 109 ANSI C63 4 2003 Product testing wa...

Страница 14: ...Mooslackengasse 17 1190 Vienna AUSTRIA info lewitt audio com 14...

Страница 15: ......

Отзывы: