5.2. Connections with Screw Terminals
5.1. Installation on TS-35 DIN Rail
Inserting the Module in the Rail:
Removing the Module in the Rail:
5.
INSTALLATION AND WIRING
The module is designed to be installed, in a vertical position, on TS-35 DIN rail. For the
best module performance and duration, avoid placing objects that could obstruct the
ventilation. Never install the modules near heat sources.
1) Attach the module in the
lower
part of the rail, as shown in the left figure below.
2) Press the module
up
wards.
1) Apply leverage using a screwdriver, as shown in the right figure below.
2) Press the module
down
wards.
9
The module has been designed for screw-type terminal electrical connections. Proceed
as follows to make the connections:
1) Strip the cables by 8mm.
2) Insert a screwdriver in hole, unscrewing the screw.
3) Insert the cable in the round hole.
4) Again, use the screwdriver to tight the screw.
5) Remove the screwdriver and make sure that the cable is tightly fastened in the
terminal.
0,2...2,5 mm²
8 mm