3.4.2 Controller Temperature
Depending on the ambient temperature and the placement of the controller additional cooling may be
required (see
). To improve cooling of the controller, place the device into a moving air stream. If
the controller is mounted in a compact area or adjacent to additional heat sources (e.g. a 2
nd
controller)
ensure that there is sufficient ventilation.
Figure 20: Temperature curves of controller LPC-2000 vs. flow and speed
(for pumping with pump head DCP-2000.2 and motors LPM-2000.x)
The above curves are measurements of the controller temperature at 25
°C
how to calculate the controller temperature for at other ambient temperatures based on this curve.
𝑇
𝐶
(
𝑇
𝐴
) ≈ 𝑇
𝐶
(𝑇
𝐴
= 25°𝐶)
⏟
𝑠𝑒𝑒 𝐹𝑖𝑔𝑢𝑟𝑒 20
+ (𝑇
𝐴
− 25°𝐶)
𝑇
𝐶
= 𝐶𝑜𝑛𝑡𝑟𝑜𝑙𝑙𝑒𝑟 𝑡𝑒𝑚𝑝𝑒𝑟𝑎𝑡𝑢𝑟𝑒
𝑇
𝐴
= 𝐴𝑚𝑏𝑖𝑒𝑛𝑡 𝑡𝑒𝑚𝑝𝑒𝑟𝑎𝑡𝑢𝑟𝑒
(Eq. 2)