3.3 Thermal Management
The driver temperature depends on the ambient and liquid temperature, as well as on the hydraulic operation
point.
and
illustrate the temperature characteristics of the motor depending on these
parameters.
Figure 17: Temperature curves for driver @ 25°C liquid temperature
(Typical data measured with DCP-30.1 pump head. Temperature is inside of the integrated motor and controller,
contact temperature of surface is below this temperature)
Figure 18: Temperature curves for the driver @ 60°C liquid temperature
(Typical data measured with DCP-30.1 pump head. Temperature is inside of the integrated motor and controller,
contact temperature is below this temperature)
77
97
117
137
157
177
0.0
0.5
1.0
1.5
2.0
25
35
45
55
65
75
85
0
1
2
3
4
5
6
7
8
[°F]
[gallons/min]
[°C]
[liters/min]
Ambient Temp = 25
C
Liquid Temp. = 25
C
Specific gravity = 1g/cm3
Viscosity = 0.7cP
Temp. Time Constant = ~40min
Recommended Operational Limit
Absolute Thermal Limit
13000 rpm
12000 rpm
11000 rpm
10000 rpm
9000 rpm
8000 rpm
7000 rpm
6000 rpm
77
97
117
137
157
177
0.0
0.5
1.0
1.5
2.0
25
35
45
55
65
75
85
0
1
2
3
4
5
6
7
8
[°F]
[gallons/min]
[°C]
[liters/min]
Ambient Temp = 25
C
Liquid Temp. = 60
C
Specific gravity = 1g/cm3
Viscosity = 0.7cP
Temp. Time Constant = ~40min
Recommended Operational Limit
Absolute Thermal Limit
13000 rpm
12000 rpm
11000 rpm
10000 rpm
9000 rpm
8000 rpm
7000 rpm
6000 rpm