User Manual for BFS-i10
www.levitronix.com
PL-3505-00, Rev00, DCO# 21-249
19
7
Appendix
7.1 Regulatory Status
7.1.1 CE Marking
We herewith declare that the
bearingless fan BFS-i10
, in its various configurations, is in conformity with the
below mentioned
European Directives
.
Machinery Directive 2006/42/EC:
The machinery directive essentially has been followed by a risk analysis, according mitigation actions and a
user manual for safe operation. For the design and testing the following standards are used as a guideline:
ISO12100
Safety for machinery
– principles for risk assessments: used for system risk analysis.
EMC Directive 2014/30/EC:
The following standards of the EMC directive are tested and confirmed at a certified laboratory:
EN61000-6-2
Generic standards, Immunity for industrial environments
EN61000-6-4
Generic standards, Emission standard for industrial environments
7.1.2 ATEX / IECEx Certification and Marking
Specific
BFS-i10
bearingless fans together with specific accessories are in conformity with the requirements
of the
Directive 2014/34/EU
and the applicable IEC standards. The following standards are tested and
confirmed at a certified laboratory.
IEC / EN 60079-0:2018
Explosive atmospheres - General requirements
IEC / EN 60079-18:2015
Explosive atmospheres - Equipment protection
by encapsulation “m”
IEC / EN 80079-36:2016
Explosive atmospheres - Non-electrical equipment for explosive atmospheres - Basic method and
requirements
IEC / EN 80079-37:2016
Explosive atmospheres - Non-electrical equipment for explosive atmospheres - Non electrical type of
protection constructional safety "c", control of ignition source "b", liquid immersion "k"
The
Levitronix
®
Ex-conform bearingless fans are marked clearly and in accordance to the
ATEX
Directive and
the relevant
IECEx
standards.
1258
II 2G Ex h mb IIC T6 Gd
II 2D Ex h mb IIIC T85 °C Db
Classification:
Category 2GD
(
Zone 1 for Gas
and
Zone 21 for Dust)
Explosion Groups:
Group IIA: Propane (IPA), Methane, Acetone, Acetaldehyde
Group IIB: Ethylene, Ethylene-glycol
Group IIC: Acetylene, Hydrogen (not carbon disulfide
)
Group IIIC: conductive dust
Thermal Classification:
Thermal classification of motor is T6 85°C / 185°F for maximum full-load operating temperature at a
maximum gas temperature of 40°C / 104°F.
UL Correspondence:
ATEX / IECEx
listing corresponds to UL hazardous location
Class 1 Division 2
.
7.1.3 Disposal of Equipment
– WEEE Directive 2012/19/EU
Follow local legislation for disposal of equipment. In the European Union (EU) marked (
) devices are
governed by the European WEEE Directive 2012/19/EU. Do not dispose with normal waste.