User Manual for PuraLev
®
600SU
www.levitronix.com
PL-4032-00, Rev06, DCO# 20-144
25
4.2 Mechanical Installation of the Pump/Motor
•
T
he motor can be fixed with four screws on the motor feet (see
).
•
As an alternative the motor can be mounted with four screws on the (see
) backside
•
The motor can be mounted in either the horizontal or vertical position. When mounting in horizontal
position it shall be mounted elevated from the bottom for at least 7 mm in order to assure sufficient
space for the pump head socket (see
•
Minimum cable bending radius according
to shall be followed for the installation of the
motor and extension/adaptor cables.
•
Each motor is identified with a unique serial number. This serial number consists of a series of
6 digits were the 5
th
and the 6
th
digit representing the manufacturing year.
Figure 30: Elevated mounting of motor
> 7 mm
Free space for
pump head socket.