Leviton Vizia RF+ VRP15-1LW Скачать руководство пользователя страница 2

Including Scene 

Capable Plug-In 

Appliance Module 

into Z-Wave

®

 

Network:

LIMITED 5 YEAR WARRANTY AND EXCLUSIONS

Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from 

the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to 

Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 201 North Service Road, Melville, New York 11747.

 This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. 

This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any 

labels or instructions. 

There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose

, but if any implied warranty is required by the applicable jurisdiction, the duration of any such 

implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. 

Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or 

loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation

. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.

 OPERATION

 TROUBLESHOOTING

DI-030-VRP15-02A-X1

© 2009 Leviton Mfg. Co., Inc.

NOTE:

 It is very important to accurately exclude 

devices from the network when moving or 

removing a device from a Z-Wave

®

 network. 

This ensures that all information has been 

removed from your Primary 

Programmer/Remote’s information table and is 

not counted on to be a part of the mesh network.

A)

 If using a Leviton Z-Wave

®

 Programmer/

Remote, Cat. No. VRCPG, press the Menu 

button and scroll down to System. Press 

the center button to select System Menu. 

Choose Advanced. Press the center button 

to select Advanced Install.

B)

 While standing close to the module, press the 

center button to <Exclude> device from the 

network.

 

NOTE:

 Only one device may be excluded at 

a time.

C) 

While the Programmer/Remote is in the 

Exclusion mode and the LED is ON on the 

Scene Capable Plug-In Appliance Module, 

press the ON/OFF button on the module. The 

Programmer/Remote will verify Exclusion and 

the LED will turn OFF on the Scene Capable 

Plug-In Appliance Module.

  If the Scene Capable Plug-In Appliance 

Module is flashing Amber while in the 

Exclusion mode, the Programmer/Remote is 

still trying to communicate with the module. 

Wait until the device stops flashing, then 

press the ON/OFF button.

Excluding Scene Capable 

Plug-In Appliance Module 

from Network:

 

Step 4

Factory Default:

If your module is not responding, or you are 

unable to control it after you have tried to 

Include/Exclude it multiple times, it may be 

necessary to reset the module to its original 

factory settings. To accomplish this, proceed as 

follows:

•  Unplug the module and wait 5 seconds. Plug 

the module back in and within 20 seconds 

press and hold the programming button until 

the LED turns Amber and then flashes Red. 

The module is now reset. Once the module is 

reset, it will be necessary to Re-Include it to a 

network before it can be used.

CAUTION:

 SETTING A DEVICE TO A 

FACTORY DEFAULT DOES NOT EXCLUDE 

THAT DEVICE FROM A NETWORK. THE 

EXCLUSION PROCEDURE MUST BE 

FOLLOWED TO REMOVE THE DEVICE FROM 

THE PRIMARY REMOTE’S INFORMATION 

TABLE. FAILURE TO DO SO MAY RESULT IN 

SYSTEM THAT IS SLOW TO RESPOND, OR 

MAY FAIL TO RESPOND TO SOME DEVICES.  

IF YOU HAVE TO RESET THE CONTROLLER 

WITHOUT EXCLUDING IT GO TO THE 

 

REMOVE FAILED MENU AND REMOVE THIS 

DEVICE FROM YOUR VRCPG REMOTE. REFER 

TO  APPLICATION GUIDE 

 

(WWW.LEVITON.COM).

 

Step 3 cont’d

 

Step 4 cont’d

Press ON/OFF Button

Wall 

Receptacle

Load plug

Scene Capable Plug-In

Appliance Module

NOTE: Remote must be in close proximity (approx. 1 ft)

to Scene Capable Plug-In Appliance Module when

including in the network.

VRCPG

Programmer/Remote

NOTE: 

For complete details on operating the 

Primary Programmer/

Remote

, refer to the 

individual device’s instruction sheet.

ON:

   

Press the ON/OFF button on the Scene 

Capable Plug-In Appliance Module or 

appropriate addressed “ON” button on the 

applicable controller. The Load will turn 

ON.

OFF:   

Press the button on the Scene Capable 

Plug-In Appliance Module or appropriate 

addressed “OFF” button on the applicable 

controller. The Load will turn OFF.

If the Scene Capable Plug-In Appliance Module 

appears to be functioning improperly, proceed 

with the following steps:

1. 

Confirm that the device is being supplied from 

a 120V, 60Hz AC source ONLY.

2. 

Confirm that the Load being controlled is in 

proper working order. Local switch, ON (check 

for burned-out bulbs).

3. 

Confirm that the Load being controlled does 

not exceed the module limit (128 devices).

4. 

Confirm that unit is programmed properly. 

Select Device List to verify that it has been 

included in the Z-Wave

®

 network.

MANUAL OPERATION OUT OF NETWORK:

 

The Scene Capable Plug-in Appliance Module 

can control the Load before being included in 

the Z-Wave

®

 network. After powering up the 

Scene Capable Plug-In Appliance Module, wait 

20 seconds then use ON/OFF button to turn the 

Load ON or OFF.

NOTE: 

If a power interruption should occur while 

the module in ON, the light load will return to its 

previous state when power is restored.

For additional information, contact Leviton’s 

Techline at 

1-800-824-3005

 or visit Leviton’s 

website at 

www..com

Protected under U.S. Patent Number 6,388,399 

and patents pending and licensed under 

U.S. Patents Numbers 5,905,442, and 5,982,103

FCC COMPLIANCE STATEMENT

This device complies with Part 15 of the FCC 

Rules. Operation is subject to following two 

conditions: (1) this device may not cause 

harmful interference, and (2) this device must 

accept any interference received, including 

interference that may cause undesired 

operation of the device.

This equipment has been tested and found 

to comply with the limits for a Class B Digital 

Device, pursuant to Part 15 of the FCC 

Rules. These limits are designed to provide 

reasonable protection against harmful 

interference in a residential installation. 

This equipment generates, uses, and can 

radiate radio frequency energy and, if not 

installed and used in accordance with the 

instructions, may cause harmful interference 

to radio communications. However, there is 

no guarantee that interference will not occur 

in a particular installation. If this equipment 

does cause harmful interference to radio or 

television reception, which can be determined 

by turning the equipment OFF and ON, 

the user is encouraged to try to correct the 

interference by one or more of the following 

measures:

•  Reorient or relocate the receiving Antenna.

•  Increase the separation between the 

equipment and the receiver.

•  Connect the equipment into an outlet on 

a circuit different from that to which the 

receiver is connected.

•  Consult the dealer or an experienced radio/

tv technician for help.

FCC CAUTION

Any changes or modifications not expressly 

approved by Leviton Manufacturing Co., Inc., 

could void the user's authority to operate the 

equipment.

Отзывы: