background image

Single Pole and 3-Way Switch

 

Standard Style Cat. No. 5241

Decora Style Cat. No. 5641

Rated: 15A-120/277VAC

INSTALLATION INSTRUCTIONS

WARNINGS AND CAUTIONS:

•  To be installed and/or used in accordance with appropriate electrical codes and regulations.
•  To avoid fi re, shock or death, TURN OFF POWER at circuit breaker or fuse. Test that 

power is off before wiring.

•  Use these devices only with copper or copper clad wire. With aluminum wire use only 

devices marked CO/ALR or CU/AL.

• 

NOTE:

  The following diagrams apply to both Standard Style and Decora Style

 Combination 

Devices.

Standard Style Switch

Cat.  No. 5241

Single pole

3-Way

Decora Style Switch

Cat.  No. 5641

Single pole

3-Way

Tools needed to install Switch:

•   Slotted, Phillips, or Robertson Screwdriver   

•   Wire Cutters

INSTALLING SWITCH:

NOTE:

 Use check boxes        when Steps are completed.

WARNING:

 To avoid fi re, shock, or death; 

TURN OFF POWER

 at circuit 

breaker or fuse and test that power is off before wiring!

Step 1

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

Identify Wall Box Wiring:

To install this combination switch, the following wires must be present 
inside wall box.

Step 2

NOTE:

  Neutral and ground connections may differ in your application. Ensure the 

device is properly grounded to system. If the wiring in the wall box does not 
resemble any of these confi gurations, consult a qualifi ed electrician.

1.  

Line (Hot-System)

2.  

Neutral (Optional)

3.  

Ground

4.  

Load - Single Pole

5.  

Travelers (To other 3-Way Switch)

SINGLE LINE HOT
(Common Feed)

1.  

Line 1 (Hot-System)

2.  

Line 2 (Hot-System)

3.  

Neutral (Optional)

4.  

Ground

5.  

Load - Single Pole

6.  

Travelers (To other 3-Way Switch)

TWO LINE HOT
(Separate Feed))

NOTE:

 

For separate feed (2 circuit) 
operation only:

 The break-off 

fi n located between the black 
screws should be removed 
before wiring. Using a standard 
slotted screwdriver, bend fi n 
until it breaks off.

Prepare Wires:

Remove 5/8" (1.6 cm) of insulation from each wire in the wall box.

Step 3

Installing your Switch:

COMMON FEED (Single Line Hot)

Single pole switch and 3-way switch on the same circuit. Light(s) 
controlled by single pole switch, other light(s) controlled by 3-way switch 
and another 3-way switch at a different location.

Step 4

PK-93604-10-00-0A

Strip 5/8"

(1.6 cm)

Strip Gage

5/8"

(1.6 cm)

"

!

!

SINGLE LINE HOT
(Common Feed)

1.  

Line (Hot-System)

2.  

Neutral (Optional)

3.  

Ground

4.  

Load - Single Pole

5.  

Travelers (To other 3-Way Switch)

Отзывы: