Leviton RZP15 Скачать руководство пользователя страница 2

lIMITED 5 YEAR WARRANTY AND EXCluSIONS

Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the 
purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to 

leviton 

Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 little Neck Parkway, little Neck, New York 11362-2591.

 This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. 

This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any 
labels or instructions. 

There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose

, but if any implied warranty is required by the applicable jurisdiction, the duration of any such 

implied  warranty,  including  merchantability  and  fitness  for  a  particular  purpose,  is  limited  to  five  years. 

leviton  is  not  liable  for  incidental,  indirect,  special,  or  consequential  damages,  including  without  limitation,  damage  to,  or 

loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation

. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.

 OPERATION

 TROuBlESHOOTING

DI-000-RZP15-00C

For additional information, contact leviton’s 

Techline at 

1-800-824-3005

 or visit leviton’s 

website at 

www.ViziaRF.com

Protected under U.S. Patent Number 6,388,399 

and patents pending and licensed under U.S. 

Patents Numbers 5,905,442, and 5,982,103

NOTE:

 It is very important to accurately 

exclude devices from the network when 

moving or removing a device from a Z-Wave

TM

 

network. This ensures that all information has 

been removed from your Primary Programmer/

Remote’s information table and is not counted 

on to be a part of the mesh network.

A)

 If using a Leviton Z-WaveTM Programmer/

Remote, Cat. No. RZCPG, press the Menu 

button and scroll down to System Setup. 

Press the center button to select System 

Setup Menu. Press the center button to 

select Network.

B)

 While standing close to the module, press 

the center button to <Exclude> device from 

the network.

 

NOTE:

 Only one device may be excluded at 

a time.

C) 

While the Programmer/Remote is in the 

Exclusion mode and the LED is ON on 

the Scene Capable Plug-In Appliance 

Module, press the ON/OFF button on the 

module. The Programmer/Remote will verify 

Exclusion and the LED will turn OFF on the 

Scene Capable Plug-In Appliance Module.

  If the Scene Capable Plug-In Appliance 

Module is flashing Amber while in the 

Exclusion mode, the Programmer/Remote is 

still trying to communicate with the module. 

Wait until the device stops flashing, then 

press the ON/OFF button. 

Excluding Scene Capable 

Plug-In Appliance Module 

from Network:

 

Step 4

This equipment has been tested and found 

to comply with the limits for a Class B Digital 

Device, pursuant to Part 15 of the FCC 

Rules. These limits are designed to provide 

reasonable protection against harmful 

interference in a residential installation. 

This equipment generates, uses, and can 

radiate radio frequency energy and, if not 

installed and used in accordance with the 

instructions, may cause harmful interference 

to radio communications. However, there is 

no guarantee that interference will not occur 

in a particular installation. If this equipment 

does cause harmful interference to radio or 

television reception, which can be determined 

by turning the equipment OFF and ON, 

the user is encouraged to try to correct the 

interference by one or more of the following 

measures:
•  Reorient or relocate the receiving Antenna.
•  Increase the separation between the 

equipment and the receiver.

•  Connect the equipment into an outlet on 

a circuit different from that  to which the 

receiver is connected.

•  Consult the dealer or an experienced radio/

tv technician for help.

FCC COMPlIANCE STATEMENT

Factory Default:

If your module is not responding, or you are 

unable to control it after you have tried to Include/

Exclude it multiple times, it may be necessary to 

reset the module to its original factory settings. To 

accomplish this, proceed as follows:
•  Unplug the module and wait 5 seconds. Plug 

the module back in and within 20 seconds 

press and hold the programming button until 

the LED flashes Amber and turns solid Red. 

The module is now reset. Once the module is 

reset, it will be necessary to Re-Include it to a 

network before it can be used.

CAuTION:

 SETTING A DEVICE TO A 

FACTORY DEFAULT DOES NOT EXCLUDE 

THAT DEVICE FROM A NETWORK. THE 

EXCLUSION PROCEDURE MUST STILL BE 

FOLLOWED TO REMOVE THE DEVICE FROM 

THE PRIMARY REMOTE’S INFORMATION 

TABLE. FAILURE TO DO SO MAY RESULT IN 

SYSTEM THAT IS SLOW TO RESPOND, OR 

MAY FAIL TO RESPOND TO SOME DEVICES.

Including Scene 

Capable Plug-In 

Appliance Module 

into Z-Wave

TM

 

Network:

 

Step 3 cont’d

 

Step 4 cont’d

 Press ON/OFF Button

Wall 
Receptacle

Load plug

Scene Capable Plug-In
Appliance Module

NOTE: Remote must be in close proximity to 
Scene Capable Plug-In Appliance Module when 
including in the network. 

RZCPG 

Programmer/Remote 

NOTE: 

For complete details on operating the 

Primary Programmer/

Remote

, refer to the 

individual device’s instruction sheet.

ON: 

Press the ON/OFF button on the 

Scene  

 

Capable Plug-In Appliance

 Module or    

 

appropriate address “ON” button on the  

 

applicable transmitter. The Load will turn  

 

ON.

OFF: 

Press the button on the Scene Capable  

 

Plug-In Appliance Module or appropriate  

 

address “OFF” button on the applicable  

 

transmitter. The Load will turn OFF.

 

If the Scene Capable Plug-In Appliance Module 

appears to be functioning improperly, proceed 

with the following steps:

1. 

Confirm that the device is being supplied    

from a 120V, 60Hz AC source ONLY.

2. 

Confirm that the Load being controlled is in  

proper working order. Local switch, ON  

 

(check for burned-out bulbs).

3. 

Confirm that the Load being controlled does  

not exceed the module limit.

4. 

Confirm that unit is programmed properly.    

Repeat “TO INSTALL” section to verify that it  

has been included in the Z-Wave™ network.

MANuAl ON/OFF PRIOR TO INCluDING 

IN NETWORK:

 The 

Scene Capable 

Plug-in 

Appliance Module can control the Load before 

being included in the Z-Wave™ network. 

After powering up the 

Scene Capable 

Plug-In 

Appliance Module, wait 10 seconds then use 

ON/OFF button to turn the Load ON or OFF.

NOTE: 

If a power interruption should occur while 

the module in ON, the light load will return to its 

previous state when power is restored.

Отзывы: