background image

LIMITED FIVE YEAR WARRANTY AND EXCLUSIONS

Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such 

five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to: Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This 

warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. 

There are no other or implied warranties of any kind, including merchantability and fitness of a 

particular purpose

, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. 

Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use 

of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. 

The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.

DI-000-OPB15-00A-X3

Step 6

Sensor Setup

:

Refer to sensor Installation Instruction sheet for 
complete details.

Step 7

Restore Power

:

Restore power at circuit breaker or fuse. INSTALLATION IS 
COMPLETE.

OPERATION

Close Relay: When the attached occupancy sensor detects motion, it will 
apply +24V to the Occupancy wire causing the relay to close.

B.   To mount inside 2.125"x 4"x 4" electrical box with 

mud-ring, refer to Figure 2. Wire per Step 2.

•    Ensure that conduit/cable entry clamp is located in corner of  

 

electrical box.

•    Dress line voltage wires to provide enough clearance in electrical  

box when device is installed.

•    Install a two-gang mud ring (not included) on electrical box.
•    Partially thread the two #6-32 screws provided into the two-gang   

mud ring, 

refer to Figure 2

.

•    Align the Power Base body so that it fits between the mounting    

holes of the electrical box and insert over mounting screws.

•    Turn counter clockwise until it reaches the stops.
•    Tighten mounting screws firmly.

  Mount power base in desired 

 

  electrical box application:

Step 4 cont’d

Figure 2 

Ceiling Installation in a 

2.125"x 4"x 4" Electrical Box

2.125"x4"x4" Electrical Box

8-32 Screws

4" Mud-ring

(2-Gang)

6-32 Screws

Sensor Power

Base

Two-Part Terminal
Connector

Ceiling

Sensor

Ceiling Mounted Sensors:
NOTE: Refer to sensor installation sheet.

•  Remove ceiling mount sensor mounting base by aligning arrows and 

pulling apart. 

Refer to sensor Installation Instructions for full  

details.

•  Remove two-part terminal connector from Sensor Power Base and  

wire per sensor Installation Instructions. 

Refer to Figure 1 and 2.

NOTE:

 Low-voltage wires should be trimmed approximately in half so the 

length can fit in mounting cavity between sensor and Power Base and no 

bare wire is exposed at the connectors.
•  Plug the two-part terminal connector into the Power Base with the 

screws facing up.

•  Align mounting indicator arrows on the Power Base and the sensor  

body and push on to Power Base and turn clockwise a quarter turn to 

secure. 

Step 5

NOTE:

 For existing 1.50" deep electrical boxes, an extension ring 

in the same shape and size can be added to allow Sensor Power 

Base to fit.

NOTES

Mount Ceiling Sensor to Power Base:

• 

Lights Flickering

  - Lamp has a bad connection.   

 

 

 

  - Wires not secured firmly with wire connectors.
• 

Lights do not turn ON

 

  - Circuit breaker or fuse has tripped. 

  - Lamp is burned out. 

  - Lamp Neutral connection is not wired. 

  - Low-voltage miswired. Verify wiring connections per appropriate    

    Wiring Diagrams. 

  - Line voltage miswired. Verify wiring connections per appropriate    

    Wiring Diagrams.
• 

Light turns ON

  - Constant motion. To Test: Adjust sensor; remove motion source. If  

    unsatisfactory, move sensor.
•  

Light turns ON too long

  - Adjust sensor.

TROUBLESHOOTING

•  For technical assistance call us at:

 

1-800-824-3005 

•  Visit our website at 

www.leviton.com

U.S. & Foreign Patents Pending

Copyright

©

 2006 Leviton Manufacturing Co., Inc.

All Rights Including Trade Dress Rights Reserved

PRODUCT INFORMATION

This equipment has been tested and found to comply with the 

limits for a Class A digital device, pursuant to part 15 of the 

FCC Rules. These limits are designed to provide reasonable 

protection against harmful interference when the equipment 

is operated in a commercial environment. This equipment 

generates, uses, and can radiate radio frequency energy and, if 

not installed and used in accordance with the instruction manual, 

may cause harmful interference to radio communications. 

Operation of this equipment in a residential area is likely to 

cause harmful interference in which case the user will be 

required to correct the interference at his own expense.

FCC COMPLIANCE STATEMENT

Отзывы: