FIGURE 2 - OVERALL CONNECTIONS DIAGRAM
ABOUT FIRE ZONES
The
Omni
IIe system supports normally open (closed for alarm), two-wire or four-wire smoke detectors. Two-wire smoke detectors
FDQRQO\EHFRQQHFWHGWR=RQHV)RXUZLUHVPRNHGHWHFWRUVFDQEHFRQQHFWHGWRDQ\]RQH$QH[WHUQDORKPHQGRIOLQH
resistor
PXVWEHXVHGIRUDOO¿UHDQGJDV]RQHV:KHQ=RQHVDUHFRQ¿JXUHGDVD6XSHUYLVHG)LUHWZRZLUHRUIRXUZLUHRU*DV
zone, the corresponding Zone Jumpers (JP11-JP14)
PXVWEH
in the “SMK” (smoke) position. Zone Jumper “JP11” corresponds to
Zone 1, “JP12” corresponds to Zone 2, “JP13” corresponds to Zone 3, and “JP14” corresponds to Zone 4.
1.
6PRNHGHWHFWRUVPXVWEHSRZHUHGIURP6:,7&+9RUDQ2XWSXWFRQ¿JXUHGDVD6:,7&+('32:(5287387
2.
End of line resistor: 1000 ohms. Maximum loop resistance EXCLUDING end of line resistor is a 150 ohms.
3.
Smoke detectors are reset when the security system is armed.
Page 5
EARTH
GROUND
SUPPLY TRANSFORMER
24V; 2A; 50/60Hz
INTERIOR
SOUNDER
SWITCHED
12 VDC
AUXILIARY 12 VDC
CONSOLE(S)
NOTES:
1. SWITCH 12V, AUXILIARY 12V, CONSOLE, AND OUTPUTS 1-8 ARE INCLUDED IN THE TOTAL DEVICE LOAD, WHICH CANNOT EXCEED 1 AMP.
2. SOUNDERS CANNOT EXCEED 1 AMP, SPLIT BETWEEN INTERIOR AND EXTERIOR HORN OUTPUTS.
OMNISTAT
THERMOSTAT(S)
EXTERIOR
SOUNDER
1A Max.
(See NOTE 1)
1A Max.
(See NOTE 1)
(See NOTE 2)
ZONE (1-4)
IN
4-WIRE FIRE ZONE
ZONE (1-4)
ZN
1K
EOL
SMOKE
2-WIRE
12V
2-WIRE FIRE ZONE
SMK
NRM
COM
OUT
WARNING
SMOKE
4-WIRE
12V
SWITCH 12V
(OUTPUT)
12V
ZN
JP11-14
(OUTPUT)
SWITCH 12V
INPUT
OUTPUT
ZN
1K
EOL
NRM
SMK
TO PREVENT RISK
FROM ELECTRIC SHOCK,
DE-ENERGIZE THIS
UNIT AND DISCONNECT
TELEPHONE LINES
BEFORE SERVICING.
OUTPUT
100 mA Max. (See NOTE 1)
OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT
ALL CIRCUITS EXCEPT FOR THE BATTERY
ARE POWER-LIMITED (CLASS II)
CONNECT CABLE
TO CONTROLLER,
PLUG MODULAR
END INTO
RJ31X JACK
ZONE
INPUT
ZONE
INPUT
ZONE
INPUT
ZONE
INPUT
ZONE
INPUT
ZONE
INPUT
ZONE
INPUT
ZONE
INPUT
ZONES 1-16 ARE CONFIGURABLE FOR BURGLARY, FIRE, TEMPERATURE, OR AUXILIARY.
2-WIRE SMOKE DETECTORS MAY ONLY BE CONNECTED TO ZONES 1-4.
INPUT
ZONE
INPUT
ZONE
INPUT
ZONE
ZONE
INPUT
ZONE
INPUT
ZONE
ZONE
INPUT
INPUT
ONLY ZONES 9-16 MAY BE CONFIGURED AS ENERGY SAVER ZONES.
ONLY ZONE 16 MAY BE USED FOR OMNISTAT THERMOSTATS.
JP11-14
ZONE
ZONE
ZONE
1K EOL
1K EOL
1K EOL
(NC)
(NO)
(NO)
(NC)
BURGLARY ZONES
WEB
VERSION