Figure 1 - Install Concrete Pad (with Anchor Bolts and Conduit/Wire run)
Figure 2 - Pull Wires through Pedestal
Figure 3 - Secure Pedestal to Concrete Pad
Figure 4 - Secure Pedestal Ground Wire
Figure 6 - Mount Charging Station to Pedestal
Figure 5 - Assemble Conduit/Wire and secure to Pedestal
Pedestal
18" min.
18" min.
Concrete
Pad
6"
6"
*NOTE: Use dedicated circuits (1 for each charging staion) if a second charging station is to be installed on the opposite side of the pedestal.
2.25" min.
3" min.
5" min.
Anchor Bolt Placement
(dimensions)
6"
6"
8"
8"
ø
1/2"
(4x)
Pedestal Base Plate (8" x 8")
Conduit
Charging Station
Conductors
* Pedestal Ground Wire
(if run through conduit - Path 2)
* Pedestal Ground Wire
(using ground strap - Path 1)
NOTE: Wires are pulled to left side of pedestal
where charging station is to be mounted.
Remove outlet box covers.
Pedestal
NOTE:
(Pedestal
ground wire
must extend
up to outlet
box openings)
Outlet Box
Cover
Outlet Box
Cover
Acorn Nut
Nut
Washer
Washer/Nut
(for leveling -
if applicable)
Charging
station
mounted
on this side
*
NOTE: Leveling nuts and washers may be used if required.
*
*
*
PATH 2
(for use with ground rod)
Direct Burial Cable
To Service
Equipment
Ground Lug
Ground Wire
for Pedestal
Ground Rod
PATH 1
(for use with ground strap)
Ground Lug
Ground Wire
for Pedestal
Ground Strap
(for metallic
conduit)
Outlet Box
Cover
Outlet Box
Opening
Metallic Conduit
To Service
Equipment
Charging Station
Conductors
NOTE:
Pedestal ground wire
must be secured before
conduit assemblies are
affixed to the pedestal.
Use a flat head screwdriver
to access the ground lug
from the opposite side
outlet box opening.
90˚ Conduit
Fitting
Flexible
Conduit
Outlet Box Cover
(with 3/4 KO)
Tightening
Nut
Cut out 3/4" hole in
outlet box cover to
accept 90˚ conduit
fitting.
Assemble conduit to outlet box
cover, pull wires through, and
secure all to pedestal by tightening
outlet box screws to pedestal.
8-1/4"
Charging Station
Conductors
NOTE: Refer to EVSE Charging Station Installation Instructions for wiring the charging station.
Use spanner screws and toothlock washers
to secure charging station to pedestal.
Repeat installation instructions for opposite
side of pedestal if a second charging station
is to be installed.
Thread top screw and washer
onto pedestal.
1.
Hang charging station over
top screw and washer.
2.
Secure and tighten bottom
screw with washer and tighten
top screw.
3.
1
2
3
NOTE:
Please visit
Leviton.com/support
for a printable version
1:1 anchor bolt pattern
DI-000-EVPED-00A
WEB
VERSION