background image

LED Indicator Light

Action

Indicates

Ethernet Link Indicator Light  

 

2

Intermittent Blink

Rx and Tx Ethernet Traffic

Ethernet Speed Indicator Light   3

Steady

Ethernet Speed is 100Mbps

Off

Ethernet Speed is 10Mbps

DALI CH1 Indicator Light   4

Intermittent Blink

Rx and Tx on the DALI channel

DALI CH2 Indicator Light   5

Communication Indicator Light   6

Steady

Power

Rapid Blink

Duplicate LumaCAN Node ID

Status Indicator Light   7

Blink once/350ms

Normal Operation

Rapid Blink

Indicated Bootloader Mode

DALI Distributed Room Controller Gateway

Cat. No. DRCDD-L0 

INSTALLATION INSTRUCTIONS

ENGLISH

WARNINGS

•  

 TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST 
THAT POWER IS OFF BEFORE WIRING!

•   To be installed and/or used in accordance with appropriate electrical codes and regulations.
•   If you are unsure about any part of these instructions, consult an electrician.

CAUTIONS

•   Use this device with 

copper or copper clad wire only.

•   For indoor applications only.
•   Save these instructions.

DRCDD-0L0 is the highly integrated LumaCAN gateway device capable of communicating with DALI lighting 
systems.  It is developed with an innovative approach for all types of commercial and domestic use.   Up 
to 64 ballasts can be connected to each channel and 16 group addresses can be created per one channel.  

The extensive functions of DRCDD-0L0 will enable multiple lighting scenarios.  Follow this guide to install and 
connect the DRCDD-0L0 gateway to the automation system.

Introduction

WARNING: TO AVOID FIRE, SHOCK, OR DEATH; 
TURN OFF POWER 

at circuit breaker or fuse and test that power is off before wiring!

1.

 

Mount the controller on the DIN rail.

NOTE:

 To remove the controller from the DIN rail, pull down on the tension spring 

and lift off.

Installation

DIN rail

To remove 

from DIN rail

2.

 

Choose the appropriate wiring for your application.

LumaCAN to DALI gateway requires Class 2 (LPS) power which ordinarily will be received over the LumaCAN 
network; however, in cases where power isn’t available over LumaCAN, an external supply may be used. DALI 
networks require power which is typically provided at the controller.  If a power supply is provided external to 
your gateway, for example if a CN100 is used, then the DALI Power In terminals should remain disconnected.   If 
however no power supply is provided, it can be provided by the controller.

 

a.

   

When to use LumaCAN powered with isolated DALI power 
supply: 

 

• When DALI requires a separate isolated power supply.

 • 

 

When DALI network is wired as Class 1 or 2. 

 • 

 

In this application the total draw from LumaCAN is 60mA for the 
gateway.

 • 

 

In this application the total draw from DALI power supply is 250 
mA per DALI channel, 500mA max.

PK-A3267-10-00-5A 

AR3128

© 2018 Leviton Mfg. Co., Inc.

Before installation, consider the items noted below.
•  Determine power supply strategy and requirements.
•  Determine LumaCAN device address and channel assignments.  This may be 

defined on your system submittal drawings.

NOTE:

 

•  DALI is NOT a PELV/SELV interface.  Under some codes, DALI must use an isolated PSU.
•  DALI Power Supply voltage must NOT exceed the maximum value (Refer to Product Specifications).

b.

 

When to use LumaCAN powered: 

 • 

 

When DALI network is wired as Class 2 and all power can be 
provided from the LumaCAN network. 

 • 

 

In this application the total draw from LumaCAN is:

1.  250mA or each DALI channel in use

2.  60mA for the gateway

•  For single channel DALI, 250mA + 60mA = 310mA

•  For dual channel DALI, 2(250mA) + 60mA = 560mA

c.

   

When to use LumaCAN Data ONLY, isolated DALI power supply, 
isolated gateway power supply: 

 

• When DALI requires a separate isolated power supply.

 • 

 

When DALI network is wired as Class 1 or 2. 

 • 

 

In this application there is no power draw from LumaCAN.

 • 

 

In this application the total draw from DALI power supply is 250 
mA per DALI channel, 500mA max.

•  In this application the total draw from the gateway power supply 

is 60mA.

2.

  LED indicator light functions:

1.

 Reset Switch 

 

 

:  to return device Ethernet 

settings to factory defaults, press and hold 
reset switch for 20 seconds until the status 
indicator light begins to blink rapidly.

3.

 Other features:

•  DALI output CH1 and CH2  8

•  DALI power input  9

•  Not in use  10

•  Ethernet jack  11

•  Termination resistor switch  12

•  LumaCAN address  13

•  Power input  14

•  Device ground  15

•  QTY 2 LumaCAN jacks  RJ45  16

•  Micro USB - 

factory use ONLY

 -  17

Operation

a.

b.

1

2

3

4

5

7

6

8

9

10

11

12

13

16

14

15

17