WARNINGS AND CAUTIONS

•  TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER

 at circuit breaker or fuse and test that power is off before wiring!

• 

To be installed and/or used in accordance with electrical codes and regulations.

•  If you are unsure about any part of these instructions, consult an electrician.
•  

The Decora

 

Smart

TM

 DW15S is not compatible with standard 3-way or 4-way switches.

•  Use only (1) Decora

 

Smart

TM

 DW15S switch in a multi-location circuit with up to 9 coordinating remote switches (DD0SR-01Z), or up to 4 matching remote switches (DD0SR-DLZ).

•  Maximum wire length from switch to all installed remotes cannot exceed 300 ft (90m).

3-Way Wiring with DD0SR-01Z Coordinating 
Remote (no LED) Application:

WARNING: 

TO AVOID FIRE SHOCK OR DEATH; 

TURN OFF POWER 

at circuit breaker or fuse and test 

that power is off before wiring!

Identifying your wiring application 
(most common):

NOTE:

 If the wiring in your wall box does not 

resemble any of these configurations, consult 
an electrician.

INSTALLING YOUR SWITCH

NOTE:

 Use check boxes           when Steps are completed.

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

 

Step 1

2

4

3

1

Single Pole

1.

  Line (Hot)

2.

  Neutral

3.

  Ground

4.

  Load 

2

5

4

3

1

3-Way

1.

  Line or Load 

(see important instruction)

2.

  Neutral

3.

  Ground

4.

  First Traveler – note color

5.

  Second Traveler – note color

 

Step 2

Terminal

Screw marked

Black (BK)

Terminal

Screw marked

Red (RD)

Terminal Label:
Use terminal for 3-way or more applications only.
For single-pole applications, DO NOT remove label.

Terminal

Screw marked

White (WH)

Terminal

Screw marked

Yellow/Red

(YL/RD)

2

4

WH

BK

RD

YL/RD

1

3

Single Pole Wiring Application:

 

Step 4a

WIRING SWITCH:
Connect wires per WIRING DIAGRAM as follows:

•  Green or bare copper wire in wall box to Green terminal 

screw.

•  Line Hot wall box wire to terminal screw marked "BK".
•  Load wall box wire to terminal screw marked "RD".
•  Line Neutral wall box wire to terminal screw marked "WH".
•  Switch terminal screw marked "YL/RD" should have Red 

insulation label affixed. 

 

NOTE:

 If insulating label is not affixed to terminal screw 

marked "YL/RD", use electrical tape to cover.

• 

Proceed to Step 5.

 FEATURES

 INTRODUCTION

Switch

Coordinating Remote (no LED)

Terminal

Screw

marked

Black (BK)

Terminal

Screw marked

Red (RD)

Terminal

Screw marked

White (WH)

Terminal

Screw

marked

Yellow/Red

(YL/RD)

2

4

Terminal

Screw marked

Yellow/Red (YL/RD)

2

4

1

WH

BK

RD

YL/RD

WH

BK

RD

YL/RD

1

Neutral to Terminal

Screw marked

White (WH)

3

3

5

5

Terminal

Screw

marked

Black

(BK)

Terminal

Screw

marked

Yellow/Red

(YL/RD)

Green

Ground

Green

Ground

Hot (Black)

Neutral (White)

Coordinating Remote (no LED)

YL/RD

YL/RD

RD

WH

RD

BK

Black

BK

WH

White

Line

120/277VAC

60Hz 

(unused)

(unused)

Load

Switch

 

Step 4b

NOTE:

 The switch must be installed in a wall box that has a Line Hot and 

Neutral connection. The coordinating remote must be installed in a wall 
box with a Load connection and a Neutral connection. A Neutral wire to 
the coordinating remote needs to be added as shown. If you are unsure 
about any part of these instructions, consult an electrician.  

NOTE:

 Maximum wire length from switch to all installed remotes cannot 

exceed 300 ft (90 m).

WIRING SWITCH (wall box with line hot connection):
Connect wires per WIRING DIAGRAM as follows:

•  Green or bare copper wire in wall box to Green terminal screw.
•  Line Hot (common) wall box wire identified (tagged) when removing  

old switch to terminal screw marked "BK".

•  First Traveler wall box wire to terminal screw marked "RD"  

(note wire color)

.

•  Remove Red insulating label from terminal screw marked "YL/RD".
•  Second Traveler wall box wire to terminal screw marked "YL/RD"  

(note wire color)

. This traveler from the switch must go to the  

terminal screw on the remote marked "YL/RD".

•  Line Neutral wall box wire to terminal screw marked "WH".

WIRING COORDINATING REMOTE 
(wall box with load connection):
Connect wires per WIRING DIAGRAM as follows:

NOTE:

 "BK" and "RD" terminals on coordinating remote are unused. 

Tighten both screws.
•  Green or bare copper wire in wall box to Green terminal screw.
•  Load wall box wire identified (tagged) when removing old switch to 

First Traveler 

(note color as above)

.

•  Second Traveler wall box wire 

(note color as above)

 to terminal screw 

marked "YL/RD". This traveler from the remote must go to the terminal 
screw on the switch marked "YL/RD".

•  Remove White insulating label from terminal screw marked "WH".
•  Line Neutral wall box wire to terminal screw marked "WH".

•  Proceed to Step 5.

 TOOLS NEEDED TO INSTALL YOUR SWITCH

Slotted/Phillips Screwdriver 

Electrical Tape 

Pliers 

 

Pencil  

 

Cutters 

 

Ruler

Changing the color of your Switch:

Your device may include color options. To change color of the face 
proceed as follows:

1

2

Insert top 
tabs and 
press in 
bottom 
tabs to 
attach

Push in 
sides at 
bottom tabs 
and pull 
outward to 
release

Preparing and connecting wires:

This switch can be wired using side wire terminal screws 
or through backwire openings. Choose appropriate wire 
stripping specifications accordingly.

IMPORTANT :

 For 3-Way applications, note that one of the screw 

terminals from the old switch being removed will usually be a 
different color (Black) or labeled Common. Tag that wire with 
electrical tape and identify as the common (Line or Load) in both the 
switch wall box and remote wall box.

 

Step 3

•  Make sure that the ends of the wires from the wall box are 

straight (cut if necessary).

•  Remove insulation from each wire in the wall box as shown.

•  For Single-Pole Application, go to Step 4a.
•  For 3-Way Coordinating Remote (no LED) Application, go to Step 4b.
•  For 3-Way Matching Remote (with LED) Application, go to Step 4c.

5/8" 

(1.6 cm)

Strip Gage 
(measure bare 
wire here)

Cut 

(if necessary)

Side Wire Connection 

Side wire terminals accept 
#14-12 AWG 

solid copper 

wire only

.

Back Wire Connection 

Back wire openings accept 
#14-12 AWG 

solid copper 

wire only

Hot (Black)

Neutral (White)

Load

Switch

BK

Black

White

RD

Green

Ground

YL/RD

Line

120/277VAC,

 60Hz 

Use terminal for
3-way or more
applications only.
For single-pole
applications,
DO NOT remove label. 

WH

3-Way Wiring with DD0SR-DLZ Matching 
Remote (with LED) Application:

 Step 4c

Switch

Matching Remote (with LED)

Terminal

Screw

marked

Black

(BK)

Terminal

Screw marked

Red (RD)

Terminal

Screw marked

White (WH)

Terminal

Screw

marked

Yellow/

Red

(YL/RD)

Terminal

Screw marked

Red (RD)

2

3

5

Neutral to Terminal

Screw marked

White (WH)

2

3

5

WH

BK

RD

YL/RD

WH

BK

RD

YL/RD

1

4

4

1

Terminal

Screw

marked

Black

(BK)

Terminal

Screw

marked

Yellow/

Red

(YL/RD)

Hot (Black)

Neutral (White)

Load

YL/RD

YL/RD

RD

BK

Black

White

Line 

120/277 VAC

60Hz

WH

BK

WH

Matching Remote (with LED)

Switch

Green

Ground

Green

Ground

RD

(unused)

NOTE:

 The switch 

must

 be installed in a wall box that has a Load and 

Neutral connection. The matching remote must be installed in a wall 
box with a Line Hot connection and a Neutral connection. A Neutral 
wire to the matching remote needs to be connected as shown.  If you 
are unsure about any part of these instructions, consult an electrician.

NOTE:

 Maximum wire length from switch to all installed remotes 

cannot exceed 300 ft (90 m).

WIRING MATCHING REMOTE 
(wall box with line hot connection):
Connect wires per WIRING DIAGRAM as follows:

NOTE:

 "RD" terminal on matching remote is unused. Tighten screw.

•  Green or bare copper wire in wall box to Green terminal screw.
•  Line Hot (common) wall box wire identified (tagged) when removing 

old switch and First Traveler to Remote terminal marked BK.

•  Second Traveler wall box wire from switch to remote terminal screw 

marked "YL/RD" 

(note wire color)

. This traveler from the remote 

must go to Yellow/Red switch terminal screw.

•  Line Neutral wall box to remote terminal screw marked "WH".

WIRING SWITCH (wall box with load connection):
Connect wires per WIRING DIAGRAM as follows:

•  Green or bare copper wire in wall box to Green terminal screw.
•  Load wall box wire identified (tagged) when removing old switch to 

Red terminal screw.

•  First Traveler Line Hot to Black terminal screw.
•  Remove Red insulating label from Yellow/Red terminal screw.
•  Second Traveler wall box wire 

(note color as above)

 to Yellow/Red 

terminal screw. This traveler from the switch must go to the terminal 
screw on the remote marked "YL/RD".

•  Line neutral wall box wire to White terminal screw.
• 

Proceed to Step 5.

 RATINGS

Incandescent

 

1800W - 120VAC, 60Hz

LED/CFL

 

5A, 600W - 120VAC, 60Hz

Fluorescent

 

15A - 120VAC, 60Hz

 

 

8A - 277VAC, 60Hz

Resistive

 

15A - 120VAC, 60Hz

Motor

 

1/2 HP - 120VAC, 60Hz

WARNINGS AND CAUTIONS

•  TO AVOID FIRE, PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT 

install to control a receptacle. 

• 

Recommended minimum wall box depth is 2-3/4".

•  Use this switch 

with copper or copper clad wire only

.

•  Save this instruction sheet. It contains important technical data along with testing and troubleshooting information which will be useful after installation is complete.
• Leviton 

Wi-Fi

®

 enabled devices rely on Wi-Fi

®

 communication. Increasing the number of Wi-Fi

®

 devices can affect Wi-Fi

®

 performance. Consult the network’s wireless access point 

specifications to determine the maximum number of supported Wi-Fi

®

 devices. For installations with a large number of Leviton Wi-Fi

®

 devices, a high performance wireless access point 

capable of supporting a large number of devices may be required.

Leviton’s Decora Smart

TM

 Wi-Fi

®

 devices are designed to streamline 

home control using the cloud, apps and connectivity with key industry 
partners. The my.Leviton.com cloud service provides an easy, secure 
way to control devices from an iOS or Android app, as well as any web 
browser. After installing your Decora Smart

TM

 device, configure it from 

the My Leviton App with just a few simple steps. You can create custom 
scenes to control your home settings. Through the my.Leviton.com site 
you can integrate with exciting and constantly expanding group of 3rd 
party partners to create a complete home automation system.

Decora Smart

TM

 devices are ideal for living rooms, bedrooms, kitchens, 

dining rooms, home offices, outdoor lighting or anywhere full control of 
lighting is desired.

WARNING: TO AVOID FIRE, PERSONAL INJURY OR DEATH 
DO NOT USE

 the remote for the control of high power heating 

appliances such as portable heaters. There can be some unexpected 
consequences if not used with care. For example, an empty coffee pot 
can be remotely turned on. If that should happen, your coffee pot could 
be damaged from overheating. If an electric heater is turned on by 
remote control while clothing is draped over it, a fire could result. This 
switch will not control lighting that is used with electronic low-voltage 
and high frequency power supply transformers, nor high pressure 
discharge lamps (HID lighting). This includes mercury-vapor, sodium 
vapor and metal halide lamps.

DI-000-DW15S-02A

•   The Decora Smart

TM

 Wi-Fi

®

 Switch provides app control and 

scheduling without the need of an automation hub

•   Compatible with my.Leviton.com cloud service for device control 

from a mobile device inside or away from the home

•  Over The Air (OTA) firmware updates via the My Leviton App
•   Single pole or three way compatible
•   Ease of installation

•   Wi-Fi

®

 Network

•  Free My Leviton App

REQUIRED

WEB 

VERSION

Отзывы: