Hot (Black)

Neutral (White)

Load

Mural

Dimmer

Blue

Yellow

Green

Ground

Black

White

Black

Line 

120VAC, 60Hz

Cap with 

Wire Connector

(OR PRIMARY SIDE OF

MAGNETIC LOW-VOLTAGE 

TRANSFORMER)

}

Wiring Diagram 1 – Single Control Application

Hot (Black)

Neutral (White)

Load

Mural

Dimmer

Blue

Blue

Yellow

Yellow

Green

Ground

Green

Ground

Black

White

Black

Line 

120VAC, 60Hz

Multi-Remote

MSØØR-1

(OR PRIMARY SIDE OF

MAGNETIC LOW-VOLTAGE 

TRANSFORMER)

}

Wiring Diagram 2 – Two Location Control Application

Hot (Black)

Neutral (White)

Load

Mural

Dimmer

Blue

Blue

Blue

Yellow

Yellow

Yellow

Green

Ground

Green

Ground

Green

Ground

Black

White

Black

Line 

120VAC, 60Hz

(OR PRIMARY SIDE OF

MAGNETIC LOW-VOLTAGE 

TRANSFORMER)

}

Multi-Remote

MSØØR-1

Multi-Remote

MSØØR-1

Wiring Diagram 3 – Three Location Control Application

7.

The brightness adjustment is located on the side of the dimmer 

(refer to Figure 1)

. Using a small, insulated

screwdriver, depress the brightness adjustment switch. To increase the minimum brightness, press the upper
half of the rocker. To decrease the minimum brightness, press the lower half of the rocker.

8.

Release the rocker. Release adjustment switch and minimum brightness is set. Check for proper operation
by tapping the lower half of the rocker so the lights turn OFF, then tapping the upper half of the rocker so the
lights turn ON. The lights will turn ON to the new minimum brightness set. If operation is not satisfactory,
repeat step 7.

9.

Attach Decora

®

 wallplate (not included). 

INSTALLATION IS COMPLETE.

NOTE:

 On the lower left corner of the switch plate, there is an air-gap switch. When servicing a controlled

fixture, pull lever out (OFF position). This will cut the power to the fixture. After servicing is complete, push the
lever in (ON position) to restore power. The lever must be pushed in all the way (ON position) for normal
operation.

COLOR CONVERSION PROCEDURE

The color of this device can be changed to suit your interior design requirements. Simply obtain a color
conversion kit of the appropriate color from your Leviton distributor and proceed as follows (please note that
wallplate must be removed).

1.

Select the color of the face you desire.

2.

The frame has snaps on its sides. Using a small screwdriver, 

gently

 remove the frame from the strap 

(refer

to Figure 2)

.

3.

Take the new frame and position it properly to the strap. Notice that the frame has a cut-out for the air-gap
switch lever. Line up the plastic snaps with the square holes in the strap. Insert the snaps on one side of the
frame into the strap.

4.

Firmly press sideways and down to slip the other snaps into place. The frame snaps in with a audible click.
Ensure that all four snaps are secure. Replace Decora

®

 wallplate. 

The color conversion is complete.

TO OPERATE:

ON:

Tap the upper half of the rocker. The lights will brighten to the last set light level.

OFF:

Tap the lower half of the rocker. The lights will dim to OFF.

BRIGHTEN:

Press and hold the upper half of the rocker to the desired light level.

FULL BRIGHT:

If the lights are OFF, double tap the upper half of the rocker. The lights will turn ON FULL
BRIGHT.

If the lights are ON, tap the upper half of the rocker once. The lights will turn ON FULL
BRIGHT.

The previous light level will remain in memory upon next ON operation 

(see above)

.

FAST OFF:

Double tap the bottom half of the rocker. The lights will immediately turn OFF.

DIM:

Press and hold the lower half of the rocker to the desired level.

BRIGHTNESS LEVEL DISPLAY:

Indicates the level of brightness when the lights are ON. Indicates the previous level of brightness when the lights are
OFF 

(refer to Figure 1)

.

NOTE: 

To alert you that there is power to the dimmer when the load is OFF, the ON/OFF LED remains ON. To

alert you that the load is ON, the ON/OFF LED remains OFF.

NOTE: 

If lights are OFF, regardless if you tap or press and hold the upper half of the rocker, the lights will go to

last set light level.

NOTE: 

If a power interruption should occur while the device is ON, the light load will return to its previous light level

when power is restored within 10 seconds.

TROUBLESHOOTING

Light does not turn ON and ON/OFF LED does not turn ON

- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Lamp is not connected to line Neutral.
- Air gap switch is open.

Dimmer does not operate

- Dimmer BLACK wire miswired to lamp and Dimmer BLUE wire miswired to LINE Hot.

Light turns ON and Dimmer works, but Multi-Remote

TM

 does not work

- There are no connections from Multi-Remote

TM

 to Dimmer.

- Multi-Remote

TM

 miswired to Dimmer.

Lights Flickering

- Lamp has a bad connection.
- Lamp power is less than 40W or 40VA.

Frame

Strap

Air-Gap 

Switch

Snaps

Push in 2 Locations

ON/OFF

LED

Brightness Level Display

(Cat. Nos. MDIØ6-1, MDI1Ø-1, MDMØ6-1 & MDM1Ø-1 ONLY)

Figure 2 – Color Conversion

PK-93079-10-00-0A

PK-93079-10-00-0A

10/16/02, 4:45 PM

2