FEATURES

Leviton's Decora

® 

Style design

Double Tap functions

Soft fade ON/OFF

Power interruption – load returns to existing state

Minimum Brightness Adjustment

ON/OFF LED indicates status of load

Brightness Level Display

Color conversion available

FCC COMPLIANCE STATEMENT

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device must not cause harmful interference, and (2) This
device must accept any interference received, including interference that may cause undesired operation.

INSTALLATION INSTRUCTIONS

WARNING:

 

TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS.

WARNING:

 

IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A QUALIFIED ELECTRICIAN.

WARNING:

 

TO AVOID OVERHEATING AND POSSIBLE DAMAGE TO THIS DEVICE AND OTHER EQUIPMENT, 

DO NOT

 INSTALL TO CONTROL A RECEPTACLE,

FLUORESCENT LIGHTING, OR A MOTOR - OR TRANSFORMER - OPERATED APPLIANCE OTHER THAN APPROPRIATE LOW-VOLTAGE LIGHTING.

CAUTION (For Incandescent Only):

 

USE WITH INCANDESCENT OR 120V HALOGEN FIXTURES ONLY.

CAUTION (For Magnetic Low-Voltage Only):

1.

USE WITH MAGNETIC LOW-VOLTAGE TRANSFORMERS, INCANDESCENT, OR 120V HALOGEN FIXTURES ONLY. USE A LEVITON ELECTRONIC LOW-VOLTAGE
DIMMER TO CONTROL ELECTRONIC (SOLID STATE) LOW-VOLTAGE TRANSFORMERS.

2.

WHEN A MAGNETIC LOW-VOLTAGE CIRCUIT IS OPERATED AT A DIM LEVEL,
WITH ALL LAMPS INOPERATIVE, EXCESS CURRENT MAY FLOW THROUGH THE
TRANSFORMER. TO AVOID POSSIBLE TRANSFORMER FAILURE DUE TO
OVERCURRENT, USE A TRANSFORMER THAT INCORPORATES THERMAL
PROTECTION OR A FUSE AT THE PRIMARY WINDINGS.

OTHER CAUTIONS:

1.

USE ONLY ONE (1) DIMMER PER LOAD. FOR REMOTE OPERATION, USE THE

LEVITON MULTI-REMOTE

TM

, CAT. NO. MSØØR-1. 

DO NOT

 USE A 3-WAY SWITCH.

2.

DISCONNECT POWER WHEN SERVICING OR CHANGING BULBS.

3.

USE THIS DEVICE ONLY WITH COPPER OR COPPER CLAD WIRE. WITH ALUMINUM WIRE USE ONLY
DEVICES MARKED CO/ALR OR CU/AL.

MULTI-GANG INSTALLATION:

When ganging dimmers, the side sections of the mounting strap must be removed. Use pliers to carefully bend
side sections back and forth until they break off 

(refer to Figure 1)

. The side sections dissipate heat, so removing

them requires a derating of the dimmer's capacity 

(refer to chart)

.

MAXIMUM BULB WATTAGE (For Magnetic Low-Voltage Only):

Low-voltage dimmers are rated in Volt-Amps (VA). The maximum bulb wattage is determined by the efficiency of
the transformer in the low-voltage lighting system. Transformer efficiencies will vary from different manufacturers;
consider 75% efficient as average. Use the chart to determine maximum bulb wattage for typical transformer
efficiency ratings.

TO INSTALL:

1.

WARNING:

 

TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE

AND TEST THAT POWER IS OFF BEFORE WIRING!

2.

Remove existing wallplate and switch or dimmer, if applicable.

3.

Remove 3/4" (1.9 cm) of insulation from each circuit conductor. Make sure that ends of conductors are straight.

4.

Connect lead wires per appropriate WIRING DIAGRAM as follows: 

WARNING:

 CONNECT A MAGNETIC

LOW-VOLTAGE DIMMER ONLY TO THE PRIMARY (HIGH-VOLTAGE) SIDE OF A MAGNETIC LOW-
VOLTAGE TRANSFORMER.

 Twist strands of each lead tightly and, with circuit conductors, push firmly into

appropriate wire connector 

(see chart for allowable wire connector and number of conductor

combinations)

. Screw connectors on clockwise making sure that no bare conductor shows below the wire

connectors. Secure each connector with electrical tape.

NOTE

: For single pole applications, cap YELLOW lead with an appropriate size wire connector. Secure

connector with electrical tape.

5.

Carefully position all wires to provide room in outlet box for dimmer. Mount dimmer into box with mounting
screws supplied.

6.

Restore power at circuit breaker or fuse. Turn the dimmer ON by pressing the upper half of the rocker. The
GREEN LED will turn OFF to indicate power to the dimmer (when the dimmer is OFF, the LED is ON).

NOTE:

 This model incorporates a trim adjustment which will allow the installer to precisely set the low end of the

dimming range to suit each installation. This adjustment is preset at the factory and should require no further
adjustments for most installations. If adjustment is required proceed as follows, otherwise continue with step 9:

For Technical Assistance Call:

1-800-824-3005 (U.S.A. Only)

www.leviton.com

LIMITED 2 YEAR WARRANTY AND EXCLUSIONS

Leviton warrants to the original consumer purchaser and
not for the benefit of anyone else that this product at the
time of its sale by Leviton is free of defects in materials and
workmanship under normal and proper use for two years
from the purchase date. Leviton’s only obligation is to correct
such defects by repair or replacement, at its option, if within
such two year period the product is returned prepaid, with
proof of purchase date, and a description of the problem to

Leviton Manufacturing Co., Inc., Att: Quality Assurance
Department, 59-25 Little Neck Parkway, Little Neck, New
York 11362-2591.

  This warranty excludes and there is

disclaimed liability for labor for removal of this product or
reinstallation. This warranty is void if this product is installed
improperly or in an improper environment, overloaded,
misused, opened, abused, or altered in any manner, or is
not used under normal operating conditions or not in
accordance with any labels or instructions. There are no
other or implied warranties of any kind, including
merchantability and fitness for a particular purpose, but if
any implied warranty is required by the applicable
jurisdiction, the duration of any such implied warranty,
including merchantability and fitness for a particular purpose,
is limited to two years. Leviton is not liable for incidental,
indirect, special, or consequential damages, including
without limitation, damage to, or loss of use of, any
equipment, lost sales or profits or delay or failure to perform
this warranty obligation. The remedies provided herein are
the exclusive remedies under this warranty, whether based
on contract, tort or otherwise.

          

Single Pole (One location) or

3-Way (Multi-location)

120VAC, 60Hz

Incandescent

                    Cat. No. MDIØ6-1, 600W

(w/brightness level display)

Cat. No. MDI1Ø-1, 1000W

                            (w/brightness level display)

                           

Magnetic Low-Voltage

       

Cat. No. MDMØ6-1, 600VA

(w/brightness level display)

Cat. No. MDM1Ø-1, 1000VA

(w/brightness level display)

Total minimum wattage must

                           exceed 40W and 40VA

For use w/ Cat. No. MSØØR-1 Multi-Remote™

INSTALLATION INSTRUCTIONS

PK-93079-10-00-0A

C O L L E C T I O N  B Y  L E V I T O N

           

 Two

  More than

            Rating               Single      Gang

  

  2 Gang

   

         600VA                450W

 375W

  300W

1000VA               750W

 600W

  525W

MAXIMUM BULB WATTAGE AT 75% EFFICIENCY

           

 Two

  More than

           Cat. No.              Single      Gang

  

  2 Gang

MDIØ6-1              600W

 500W

  400W

MDI1Ø-1             1000W

 800W

  700W

MDMØ6-1             600VA      500VA

  400VA

MDM1Ø-1           1000VA     800VA        700VA

MAXIMUM LOAD PER DIMMER FOR MULTI-GANG

PK-93079-10-00-0A

Upper

Rocker

Air Gap

Switch

ON/OFF

LED

Lower

Rocker

Minimum Brightness 

Adjustment Switch

Brightness Level

Display

Mounting Strap

Side Sections

Figure 1 –  Dimmer Functions

WIRE CONNECTOR / # OF CONDUCTOR COMBINATION CHART

1- #12 w/ 1 to 3 #14, #16 or #18
2- #12 w/ 1 #14 w/ 1 #16 or #18
2- #12 w/ 1 #16 w/ 1 or 2 #18
2- #14 w/ 1 to 3 #16, #18 or #20
4- #16 w/ 1 or 2 #18, #20 or #22
1- #14 w/ 1 to 4 #16, #18 or #20
2- #14 w/ 1 to 3 #16, #18 or #20

2- #14 w/ 1 #16 w/ 1 or 2 #18 or #20
3- #14 w/ 1 or 2 #18 or #20
4- #14 w/ 1 #16 or #18
2- #16 w/ 1 #18 w/ 1 or 2 #20 or #22
1- #14 w/ 1 #18 w/ 1 to 3 #20
3- #14 w/ 1 #16 w/ 1 #18, #20, #22
3- #14 w/ 1 #18 w/ 1 #20 or #22

PK-93079-10-00-0A

10/16/02, 4:45 PM