LED Illuminated 3-Way Switch

Cat. No. L5613

Rated: 15A-120/277V AC

DI-000-L5613-20A

WARNINGS
•  TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER

 AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING!

•  

TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH ELECTRICAL CODES AND REGULATIONS.

CAUTIONS
• 

Use this device 

with copper or copper clad wire only

.

• To clean use a damp cloth with mild soap. 

DO NOT

 use disinfecting products, including foggers, sprays or other types of atomized cleaning agents.

1.

 

 WARNING:

 

TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER

 AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF  

BEFORE WIRING!

2A.

 

TO QUICKWIRE™: 

Remove insulation per strip gauge on device approx. 5/8" (1.6 cm). Insert straight #14 AWG solid copper wires into round 

Quickwire™ holes. Quickwire™ terminals accept #14 AWG solid copper wires ONLY! For circuits with #12 AWG solid copper or copper clad wires,  
use terminal screws instead. To replace or rewire after Quickwiring, gently press the tip of a small screwdriver in the release slot and back the wire  
out gradually.

2B.

  

TO SIDE WIRE: 

Remove insulation approx. 3/4" (1.9 cm). Loop wires clockwise 3/4 turn around terminal screws.  

Tighten screws over wire loops to 14-18 in lbs.

2C.

 

TO BACK WIRE: 

Remove insulation per strip gauge on device approx. 5/8" (1.6 cm). Insert straight wires under clamps of appropriate terminal screws. 

Tighten screws firmly.

2D.

 The GROUND terminal on this device may be wired in the traditional side wire method or as follows: Slide wire straight between screw head and tab and 

insert into hole per 

FIGURE 1

 (no looping of wire required). Firmly tighten screw over wire.

3. 

Back and side wire terminal screws accept up to #12 AWG copper or copper clad wire.

4. 

Mount device using long mounting screws. Attach wallplate.

5. 

Restore power at circuit breaker or fuse. 

Installation is complete.

INSTALLATION

ENGLISH

For Technical Assistance Call: 1-800-824-3005 (USA Only) or 1-800-405-5320 (Canada Only) www.leviton.com

LIMITED 2 YEAR WARRANTY AND EXCLUSIONS

Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship 
under normal and proper use for two years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option. 

For details visit 

 www.leviton.com or call 1-800-824-3005.

 This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this 

product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not 
in accordance with any labels or instructions. 

There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose

, but if any 

implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to two years. 

Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits 
or delay or failure to perform this warranty obligation

. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.

FOR CANADA ONLY

For warranty information and/or product returns, residents of Canada should contact Leviton in writing at 

Leviton Manufacturing of Canada ULC

 to the attention of the  

Quality Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at 1 800 405-5320.

Ground Insert Hole

Orifice d’insertion

Orificio para insertar 

GROUND

IN

S

ERT

HOLE

Tab / 

L

a

nguette

 / 

Lengüeta 

Ground 

S

crew

Vis de terre

Tornillo a Tierra

Conductor

Fil 

Conductor

Figure 1 

/ Figura 1

Wiring Diagram / 

S

chéma de câblage / Diagrama de Cableado

Load

Ch

a

rge

Carga

Line Hot (Black)

Ligne 

a

ctif (noir)

Linea Fase (Negro)

Black /

 Noir / 

Negro

Neutro (Blanco)

Neutre (Bl

a

nc)

Neutral (White)

1

1

2

2

Travelers Brass 

S

crew to Brass 

S

crew

Conducteur ltiner

a

nt vis l

a

iton à vis l

a

iton

Viajeros Tornillo Latón a Tornillo Latón

2

To Common Terminal (Black 

S

crew)

À l

a

 borne commune (Vis noire)

A Terminal Común (Tornillo Negro) 

1

3

Ground (Green 

S

crew)

Terre (vis verte)

Tierra (Tornillo Verde)

3

3