LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone
else that this product at the time of its sale by Leviton is free of defects in materials
and workmanship under normal and proper use for five years from the purchase
date. Leviton’s only obligation is to correct such defects by repair or replacement, at
its option, if within such five year period the product is returned prepaid, with proof of
purchase date, and a description of the problem to
Leviton Manufacturing Co., Inc.,
Att: Quality Assurance Department, 201 North Service Road, Melville, New York
11747. This warranty excludes and there is disclaimed liability for labor for removal of
this product or reinstallation. This warranty is void if this product is installed improperly
or in an improper environment, overloaded, misused, opened, abused, or altered in any
manner, or is not used under normal operating conditions or not in accordance with any
labels or instructions.
There are no other or implied warranties of any kind, including
merchantability and fitness for a particular purpose, but if any implied warranty is
required by the applicable jurisdiction, the duration of any such implied warranty, including
merchantability and fitness for a particular purpose, is limited to five years.
Leviton is not
liable for incidental, indirect, special, or consequential damages, including without
limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay
or failure to perform this warranty obligation. The remedies provided herein are the
exclusive remedies under this warranty, whether based on contract, tort or otherwise.
PK-93020-10-00-2A
© 2012 Leviton Mfg. Co., Inc.
• Position all wires to provide room in
outlet wall box for device.
• Ensure that the word "TOP" is
facing up on device strap.
• Partially screw in mounting screws
in wall box mounting holes.
• Restore power at circuit breaker or fuse.
• Wait 40 seconds for sensor to power up.
• For IPS02, lights will automatically turn ON
after power is applied.
• For IPV02, press push pad. Lights should
turn ON.
If lights still do not turn ON, refer to the
TROUBLESHOOTING section.
Step 5
Restore Power:
Restore power at circuit breaker or
fuse.
Installation is complete.
Step 7
Device Mounting:
TURN OFF POWER AT CIRCUIT
BREAKER OR FUSE.
Step 6
Installation may now be
completed by tightening
mounting screws into wall
box. Attach wallplate.
OPERATION
NOTE: Dress wires with a bend as
shown in diagram in order to relieve
stress when mounting device.
For additional information, contact Leviton’s Techline at
1-800-824-3005 or visit Leviton’s website at www.leviton.com
This product is covered by U.S. Pat. No. 7,924,155 & corresponding foreign patents.
© 2012 Leviton Manufacturing Co., Inc. All Rights Including Trade Dress Rights Reserved
DECORA is a trademark of Leviton Manufacturing Co., Inc. registered in the United
States, Canada, Mexico and China.
ADJUSTMENT SETTINGS
TROUBLESHOOTING
Lights do not operate with push pad and LED indicator does not
blink when motion is present:
• Ensure proper ground connection is present in the wallbox.
When confirmed, verify wiring connections to sensor.
Lights do not switch ON when motion is detected (IPS02):
• Motion is beyond sensing range, move closer to switch.
• Adjust the light level adjustment toward lighter (counterclockwise),
depending on room conditions.
Lights always stay ON:
• Check time delay settings and compare to how long the lights stay ON.
• Ensure that no motion occurs in coverage area for time selected.
• Check that switch is not installed near a heat source (e.g., stove, lights,
heat vents) or detecting motion from an adjacent area (e.g., hallway
traffic). If so, switch may have to be relocated.
Lights do not turn ON - IPV02:
• Check that control is installed correctly.
• Check that power is ON.
• Check that light bulb is functioning.
NOTE: If problems continue, consult an electrician.
IPS02
Auto On: Lights will automatically turn ON when
room is occupied or motion is detected.
The IPS02 will switch lights OFF when no
motion is detected in un-occupied room after set
period of time.
Time delay adjustment: Refer to section on
Adjustment settings.
The IPS02 will manually turn-on lights or the
load by depressing the ON/OFF paddle on the
device. The IPS02 can be set to only turn ON by
the pushpad (no automatic ON operation) by adjusting the ambient light
control to the "0" position.
IPV02
Manual On: The IPV02 requires the user to manually turn-on lights or the
load by depressing the ON/OFF paddle on the device.
The lights or load will automatically turn-off when the room is left
un-occupied for a set period of time.
Time delay adjustment: Refer to section on Adjustment settings.
Locator Light LED:
LED blinks once every 2 seconds when motion is detected and if the load
is ON or OFF.
FCC COMPLIANCE STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to following
two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation of the device.
This equipment has been tested and found to comply with the limits for a Class B Digital
Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment OFF and ON,
the user is encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving Antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
• Consult the dealer or an experienced radio/tv technician for help.
FCC CAUTION
Any changes or modifications not expressly approved by Leviton Manufacturing Co., Inc.,
could void the user's authority to operate the equipment.
SENSING AREA COVERAGE
Field-of-View (Horizontal)
Side (Vertical) Field-of-View
Testing your Device prior to mounting in
wall box:
1. With power restored and wallplate removed, remove face of device to
expose setting controls, see color change instructions in page 1. Use
your finger or a small screwdriver to adjust the light sensitivity and time
settings on the device as follows:
Light Level Adjustment:
• Turn the control clockwise. Lights will turn ON in lighter conditions.
• Turn the control counter clockwise. Lights will turn ON in less lighting
conditions.
Time Selection:
• Adjust the time selector to the desired length of time the lights are to
remain ON. Lights will remain ON from 30 seconds to 30 minutes after
the room is vacated.
• Turn the control clockwise . Lights will remain ON up to 30 minutes.
• Turn the control counter clockwise. Lights will remain ON up to 30
seconds.
2. Test that the light level and time selection are as desired. If not, repeat
adjustments until satisfied.
3. Mount wallplate. INSTALLATION IS COMPLETE.
Lens
Push
Pad
Locator
Light
1.5m
5ft
30ft
9.1m
30ft
9.1m
6ft
1.7m
1.8m
6ft
5ft
1.5m
30ft
9.1m
1.4m
4ft
8.4m
27ft
2.1m
7ft
1.5m
5ft
1.2m
4ft
1.7m
6ft
2.6m
8ft
Light Level
Adjustment
Time
Selection
1 2
0 3
1 2
0 3
0
1
2
3
Settings
30 Sec
5 Min
15 Min
30 Min
Time
NOTE: To operate the IPS02 as a vacancy sensor (Manual ON/Auto OFF):
rotate the light level sensitivity fully counter clock wise.
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact
Leviton in writing at
Leviton Manufacturing of Canada Ltd to the attention of
the Quality Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec),
Canada H9R 1E9 or by telephone at 1 800 405-5320.