Single-Pole Wiring Application:
• Restore power at circuit
breaker or fuse.
• Carefully holding control as
shown, rotate knob to the MAX
position. Fan should turn ON
to highest level. Rotate knob to
the remaining levels: HI, MED,
and LO. Fan speed should
change accordingly.
If fan does not turn ON, refer
to the TROUBLESHOOTING
section.
• Fan does not turn ON or does not run Multi-speed
- Circuit breaker or fuse has tripped.
- Fan Neutral connection is not wired.
- Fan has burned out.
For non-standard wiring applications, refer
to Wire Nut and Conductor Size Chart
Connect wires per WIRING DIAGRAM as follows:
Screw wire nuts on clockwise making sure no bare
conductors show below the wire connectors. Secure each
connector with electrical tape.
• Green control Ground lead to Green or bare copper
wire in wall box.
• Black control lead to Line (Hot) wall box wire removed
from old switch.
• Red control lead to remaining wall box wire.
•
Proceed to Step 6.
Testing your Fan Speed Control prior to
mounting in wall box:
Fan Speed Control Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
Restore Power:
Restore power at circuit breaker or
fuse.
Installation is complete.
Step 6
Step 7
OPERATION
TROUBLESHOOTING
Step 8
Step 9
Installation may now be completed
by carefully positioning
all wires to provide room in wall box
for control. Mount control
into box with mounting screws
supplied. Attach wallplate.
ON
Rotate bottom control knob to one of the
four levels: MAX, HI, MED, and LO
– Fan will increase or decrease in speed
respectively for desired level.
OFF
Rotate bottom control knob fully counter
-
clockwise to the OFF position – Fan will
turn OFF.
WIRE NUT / # OF CONDUCTOR
COMBINATION CHART
1- #12 w/ 1 to 3 #14, #16 or #18
2- #12 w/ 1 or 2 #16 or #18
1- #14 w/ 1 to 4 #16 or #18
2- #14 w/ 1 to 3 #16 or #18
Step 5
con’t
O
FF
MA
X HI MED
LO
O
FF
MA
X HI MED
LO
O
FF
M
AX
HI MED LO
Hot (Black)
Neutral (White)
Fan
Fan Speed
Black
Green
Ground
Black
White
Red
Line
120VAC, 60Hz
O
FF
MA
X HI MED
LO
PRODUCT INFORMATION
• For technical assistance, contact us at
1-800-824-3005.
• Visit our website at
www.leviton.com.
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation
is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to
Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little
Neck Parkway, Little Neck, New York
11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened,
abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is
required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage
to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
DI-000-RTF01-02C