Single-Pole Wiring Application:
Connect wires per WIRING DIAGRAM as follows:
Screw wire nuts on clockwise making sure no bare conductors
show below the wire connectors. Secure each connector with
electrical tape.
•
Green dimmer Ground lead to Green or bare copper
wire in wall box.
•
Black dimmer lead to any wall box wire removed
from old switch.
•
Red dimmer lead without insulating label to remaining
wall box wire.
•
Remaining Red dimmer lead should have Red insulation
label affixed.
NOTE: If insulating label is not affixed to Red lead, use a
small wire nut or electrical tape to cap off. Proceed to Step 6.
3-Way Wiring Application:
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation
is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little
Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened,
abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied
warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without
limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
Connect wires per WIRING DIAGRAM as follows:
Screw wire nuts on clockwise making sure no bare
conductors show below the wire connectors. Secure each
connector with electrical tape.
• Green dimmer Ground lead to Green or bare copper wire
in wall box.
• Black dimmer lead to tagged (common) wall box wire
identified when removing old switch.
• Remove Red insulating label from Red lead.
• Any Red dimmer lead to any of the remaining
wall box wires.
• Remaining Red dimmer lead to remaining wall box wire.
Testing your Dimmer prior to mounting in wall
box:
Minimum Brightness Adjustment:
Dimmer Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
Step 7
Restore Power:
Restore power at circuit breaker or
fuse. Installation is complete.
OPERATION
NOTE: The indicator light will illuminate when the dimmer is in the
OFF position to facilitate access in the dark.
NOTE: If using the dimmer in a 3-way application, the lights will
turn ON at brightness set on dimmer's slide control lever. The
lighting level can be controlled from either the dimmer or the
switch location.
TROUBLESHOOTING
•
Lights Flickering
- Lamp has a bad connection.
- Wires not secured firmly with wire connectors.
•
Light does not turn ON and ON/OFF LED does not turn ON
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Lamp Neutral connection is not wired.
NOTE: If further information is needed in identifying the HOT wire
in a 3-Way application, go to
Leviton's website at www.leviton.com.
For non-standard wiring applications, refer
to Wire Nut and Conductor Size Chart
PK-93182-10-00-2B
Step 5b
Hot (Black)
Neutral (White)
Load
Dimmer
3-Way Switch
Red
Black
Green
Ground
Green
Ground
Black
White
Red
Line
120VAC, 60Hz
Common
Terminal
(Black Screw)
Step 6
Step 5a
Hot (Black)
Neutral (White)
Load
Dimmer
Black
Green
Ground
Black
White
Red
Line
120VAC, 60Hz
Red
Insulating
Label
Step 9
WIRE NUT / # OF COND.
COMBINATION CHART
1- #12 w/ 1 to 3 #14, #16 or #18
2- #12 w/ 1 or 2 #16 or #18
1- #14 w/ 1 to 4 #16 or #18
2- #14 w/ 1 to 3 #16 or #18
Black
Red
Neutral
Green
Ground
Red
This wire is used in 3-way installations only.
For single pole installations, do not remove this
insulating label.
Black
Tag
Red
Green
Red
Neutral
Ground
Step 5b
cont'd
•
Restore power at circuit breaker or
fuse.
•
Carefully holding Dimmer as
shown, move slider control lever to
highest position. Lights should turn
ON to brightest level. If lights do not
turn ON, depress push-button switch
once. Lights should turn ON to
brightest level.
If lights still do not turn ON, refer
to the TROUBLESHOOTING
section.
Installation may now be completed
by carefully positioning
all wires to provide room in wall box
for dimmer. Mount dimmer
into box with mounting screws
supplied. Attach wallplate.
ON/OFF:
Depress push-button switch to ON
position - Lights will turn ON.
Depress push-button switch to OFF
position - Lights will turn OFF.
BRIGHTEN & DIM:
Move slider control lever - Lights will
BRIGHTEN or DIM.
Insert wires
straight then twist
clockwise
Insert wires
straight then twist
clockwise
Electrical
Tape
Electrical
Tape
Step 8
This Dimmer incorporates a
minimum brightness adjustment
that allows you to set the level of
light when the slider control lever is
in the lowest position.
Move slider to the lowest position.
Using a small, insulated screwdriver,
rotate the adjustment screw as
shown until the desired level of
minimum brightness is obtained.
PRODUCT INFORMATION
• For technical assistance, contact us at
1-800-824-3005
• Visit our website at
www.leviton.com