OVERVIEW

The Room Remote can be added to a Leviton

®

 bitwise™ system utilizing iOS

®

/Android

®

 Devices 

for control or can be used as the sole point of control. Each system needs at least one RF receiver 
and a compatible 

Leviton

 

bitwise

 Controller (see Requirements for details). This document will guide 

you through connecting the required hardware. For programming, please refer to the Room Remote 
Programming Guide.

REQUIREMENTS
Hardware

•   Room Remote - BWRMT
•   RF to Serial Receiver – BWRRR
•   Compatible 

Leviton bitwise 

Controller - BWBC1,BWBC2, Gen 2 BWBC4  

(Not compatible with Gen1 BWBC4)

Software

•   Project Editor - v1.9.60 or later
•   BWBC1 Firmware - v131115-0.1fw
•   BWBC2 Firmware - v131115-0.1fw
•   BWBC4 Firmware – v1.3.16

CONNECT THE RF RECEIVER TO THE CONTROLLER SERIAL PORT

Each RF Receiver is capable of supporting up to 255 RF Room Remotes. The RF Receiver connects 
via RS232 to a compatible 

Leviton bitwise 

Controller. In most cases, it will be easiest to use a serial 

port with terminal connectors rather than the DB-9. The remaining instructions assume you are using a 
serial port with terminal block connections.

NOTE:

 If you need to extend the cable for the RF Receiver we recommend using 3 conductor shielded 

cable or 2 pairs of Cat5/6 network cable. If using Cat5/6, use the Orange pair for signal and ground 
and the Green pair for Power and ground. (Yes, connect ground to one conductor of each pair).

RF RECEIVER PLACEMENT

Try to place the RF Receiver in a central location close to where the remote(s) will be used, away 
from sources of RF noise and large amounts of metal (refrigerators, furnaces etc…). The antenna 
whip should be vertical in most cases but may be adjusted as necessary for optimal reception.

ADDRESS THE REMOTE(S)

1.   Hold the “OK” and “B” buttons until the res status LED turns solid red (

figure 1

).

2.   Enter a THREE digit address (001-255) using the numeric keys.
3.   Press the “OK” key.

The LED will blink twice if the process was successful and 5 times if an invalid sequence was entered 
or the procedure timed out.

CONTACT

Technical Support:

 1-800-824-3005

Email:

 [email protected]

[email protected]

Web:

 www.leviton.com/automation

ROOM REMOTE WIRE

BITWISE CONTROLLER RS232 PORT

Black

GND - Ground

White

RXD - Receive

Red

4+12 VDC - Power

Press and Hold

at the same time

FIGURE 1