VOI-8000 User’s Guide
Overview
44
Application B: FXS / FXO combination
Application-B has three possible connections. The B-1 connection is a normal trunk connection
between the CO switch and PBX. The B-2 connection is identical to the A-1 connection
mentioned in Application A. The B-3 connection is used to connect the PBX and gateway
through the internal analogue lines provided by the PBX. In this case, the FXO module has to be
used, and the FXO ports will serve the same roles as the analogue telephone sets.
Note: If the PBX used in the B-3 connection is a digital type, a certain analog terminal adapter
is needed to provide an analog interface to the FXO module.
In this application, The caller in the B-2 connection can use the Gateway through its FXS module
to communicate with the party on the other end in the B-3 connection. The phone call is
forwarded through the FXS module in the B-2 Gateway and is received by the FXO module in
the B-3 gateway, which is connected to the PBX, which will then switch to the dedicated
terminal.
The same caller can also use the feature that the Gateway provides to redial the local number
through the PBX, to the public switch, in order to reach the person inside the region that the
public switch serves.
Fax
Telephone
FXS
FXS
IP
Telephone
Telephone
PBX
Telephone
FXS
FXO: Up
to 8 lines
Public Switch
Telephone
Fax
Connection B-1
Connection B-2
Trunk
Fax
Connection B-3
Содержание VOI-8000
Страница 1: ...VOI 8000 User s Guide Preface i LevelOne VOI 8000 H 323 Modular Gateway User s Manual...
Страница 60: ...VOI 8000 User s Guide Overview 52 11 H 323 Dest 210 243 230 10 1720 TCP 12 H 323 Dest 210 243 230 20 1720 TCP...
Страница 64: ...VOI 8000 User s Guide Overview 56 A 3 ATPM Hunt Group Table Hunt Type Hunt Group ID 1 2 List of Destination IDs...