User Manual
Publication date: June, 2005
Revision A1
132
Function name:
Loopback Test
Function description:
In the Loopback Test function, there are two different loopback tests. One is
Internal Loopback Test and the other is External Loopback Test. The former
test function will not send the test signal outside the switch box. The test signal
only wraps around in the switch box. As to the latter test function, it will send
the test signal to its link partner. If you do not have them connected to active
network devices, i.e. the ports are link down, the switch will report the port
numbers failed. If they all are ok, it just shows OK.
Note: Whatever you choose Internal Loopback Test or External Loopback Test,
these two functions will interfere with the normal system working, and all
packets in sending and receiving also will stop temporarily.
Fig. 3-70
Содержание ProCon GSW-2690
Страница 30: ...User Manual Publication date June 2005 Revision A1 26 Fig 2 13 Office Network Connection...
Страница 140: ...User Manual Publication date June 2005 Revision A1 136 Upload Log Upload log data through tftp Clear Log Clear log data...