background image

 

                                                                               

 

13

 

Port Specific Control 

 

 

Port Enable: 

enabling the port. This function is co-responding with “Master 

Enable” function.

 

 

Bypass Detection: 

bypass the detection function.    Normally the system will try 

to detect the 25k

 resistor in an 802.3af compliant PD device. If the PD doesn’t 

follow by IEEE 802.3af standard, you can enable this option to skip the detection 

on PD. When you enable this function, the system will not perform the 25

 

resistor detection for PD and directly transmit the power to PD. This function can 

be cooperating with “PD discover R (ohms)” function in System setup & Control 

section for non-standard compliant PD device.

 

[Note]

 after setting the Bypass Detection function, please unplug and then plug in 

the PD device. 

 

Bypass Classification: 

the system will skip the power classification and directly 

transmit the power to PD when this function is enabling. Normally the system will 

try to classify the 802.3af compliant PD device by checking the current class level. 

The following table is a standard current classification level table. 

 

[Note]

 after setting the Bypass Classification function, please unplug and then plug 

in the PD device.

 

 

Power Device 

Power (W) 

Classification Current 

(mA) 

Class 

Usage 

MIN MAX MIN MAX 

0 Default 

0.44 

12.95 

1 Optional 

0.44 

3.84 

12 

2 Optional 

3.84 

6.49 

17 

20 

3 Optional 

6.49 

12.95 

26 

30 

Optional 

Reserved for future use

36 

44 

Table of Power Device Classification Levels 

 

 

LED Status Indicators: 

current LED indicator display – green, yellow, and red. 

Содержание POH-0850TX

Страница 1: ...POH 0850TX 19 8 port MidSpan POE HUB USER MANUAL...

Страница 2: ...Indicators 3 Rear Panel 4 Power On 4 Network Application 5 3 Software Utility Installation 6 4 GUI Management 9 Connecting to PoE 9 System Setup Control 10 System Information 11 Device Setting 11 Port...

Страница 3: ...ng Ethernet switches and networked devices Because the Power Sourcing Equipment PSE tests whether a networked device is PoE capable power is never transmitted unless a Powered Device is at other end o...

Страница 4: ...ort Plug and Play feature for PD Package Contents Unpack the contents of the 8 port Power over Ethernet Hub and verify them against the checklist below POS 0850TX 8 port Power over Ethernet MidSpan Hu...

Страница 5: ...mension is 440mm x 224mm x 44mm Lx W x H Front Panel The Front Panel of the POH 0850TX consists of 8x RJ 45 Ethernet ports LED indicators and one console port Figure 2 1 The appearance of POH 0850TX 8...

Страница 6: ...e The Power Off LED is flashing when No PD attached And the LED goes off when PD attached The corresponding power forwarding LED will then go ON or OFF depending on switch action Rear Panel The 3 pron...

Страница 7: ...led in more appropriate position for better performance The following figure is an example of network application for Power over Ethernet Hub Powered Device ex SOHO switch or Wireless AP 1 2 3 4 5 6 7...

Страница 8: ...ility provides GUI interface and user can easily to start with it The software utility supports Windows environment Window 98 2000 and XP Please follow the below steps to install the software utility...

Страница 9: ...7 Figure 3 2 6 When installation finishes click OK button to finish See Figure 3 3 Figure 3 3 7 To run the software utility go to Star Program Power Over Ethernet...

Страница 10: ...8 8 If you want to remove the software utility go to Star Control Panel Remove Add application Power Over Ethernet...

Страница 11: ...rial Link Setup function You will see the main utility interface as figure 4 1 Figure 4 1 The GUI management interface The GUI management is divided into three parts System Setup Control main system l...

Страница 12: ...do the port controlling please remove the PD device and enable this function to calibrate internal system PD Discovery R ohms set the PD resistor value range for the system detecting The default value...

Страница 13: ...system provided to PD Figure 4 3 System Information interface Device Setting Enable Auto Refresh It allows the system auto refresh the system parameters The system auto refresh in every 2 seconds Load...

Страница 14: ...12 Figure 4 4 Device Setting interface...

Страница 15: ...tting the Bypass Detection function please unplug and then plug in the PD device Bypass Classification the system will skip the power classification and directly transmit the power to PD when this fun...

Страница 16: ...connected PD device status is normal Overload It means the current is over the PD current classification limited 475mA 48V DC that the situation happens over 50msec Mode Status display the PD current...

Страница 17: ...n function the class current value will not show in here Please refer to the following table for output value Class Usage Maximum power of levels at output of PSE 0 Default 15 4 Watts 1 Optional 4 0 W...

Страница 18: ...Mid Spain Management utility Support Microsoft windows based application for power management Plug and play for standard PD and without any software configuration System setup and control System calib...

Страница 19: ...class LED System power Per port power Forwarding power off Power AC 100 240V 50 60 Hz 130 Watts IEC power socket with fuse and power switch Power consumption 130 Watts maximum Cooling 2 x DC fan Weig...

Страница 20: ...m can be accessed from PC running the system utility program The pin assignments used to connect to the serial port are provided in the following tables Figure 6 1 DB 9 Console Port Pin Numbers DB 9 P...

Страница 21: ...19 Console Port to 9 Pin DTE Port on PC Switch s 9 Pin Serial Port CCITT Signal PC s 9 Pin DTE Port 2 RXD RXD 3 TxD 3 TXD TXD 2 RxD 5 SGND SGND 5 SGND No other pins are used...

Отзывы: