Explanation for LED indicators
The LED indicators serve as device status monitoring and
error display. The following table explains each LED
indicator.
Table.1 Descriptions of LEDs
LED
Status
Description
PWR
Green
Device active
POE P1~P8
Yellow
PoE function active and
Connected PD is supplied with PoE
OFF
PoE function deactivated or
No PD identified
L/A
P1~P8
Green
Link to port
Blink
Data transfer to port
SPD
P1~P8
Green
Transfer rate is 1000Mbps
OFF
Transfer rate is 10/100Mbps
Technical parameters:
1.
Standard Protocol:
IEEE 802.3 10 Base-T
IEEE 802.3u 100Base-TX
IEEE 802.3ab 1000Base-T
IEEE 802.3x flow control
IEEE 802.3af PoE
2.
Connectors:
8
×
UTP RJ-45 connector with POE function
3.
Operation mode:
10/100/1000Mbps auto-negotiation mode
4.
5.
PSE Pinout: PIN1/2: Pos(+), PIN3/6:Neg(-)
6.
Operation temperature: -20
℃
~70
℃
7.
Storage temperature: -40
℃
~75
℃
8.
Operation humidity: 5%-90% non-condense
9.
Storage humidity: 5%-90% non-condense
10.
Twisted Pair cable: Cat5 UTP cable
11.
Dimensions: 30
×
170.5
×
80.5mm (H x W x D)
Warning:
1.
This product is suitable for indoor application.
2.
The cable distance between the switch and PC should not
exceed 100 meters for UTP cable.
3.
Cat.3/4/5 cable may be used in 10Mbps operation.
However, Cat.5 UTP or better data grade cable must be
employed for 100/1000Mbps operation.
4.
The appliance inlet is used as the disconnect device and
shall remain readily operable at all time.
Trouble shooting:
1.
Bad performance
Please check the transfer rate (10Mbps, 100Mbps or
100Mbps) and the duplex status (full duplex or half
duplex) of both sides. Make sure both sides are set to
identical status.
2.
Link failure :
Check the L/A LED on the switch try another port on
the switch make sure the cable is well installed make sure
the cable is the right type power off the device for a while
and power it on again.