Mini Console
3-18
Once a loop is detected (which takes about one second), it will disable that
port. The port number frame will blink indicating it has been temporarily
isolated. Every 8 minutes, the port will be released to see if it is still looping.
The function of LOOP ISOLATE is disabled at the time it shipped from
manufacturer. You have to enable the function through Mini-Console. The
command sequence is:
UNIT CONFIG > LOOP ISOLATE > ENABLE><Enter and hold>
After the command is entered, it will be saved in the EEPROM.
Sub-Menu
Command
To Set Press:
Loop Isolation
Enable
Enter and hold
Disable
Enter and hold
Back
Enter
Table 3.9
Loop Isolation
Lock the Console
Setting this option to
Enable
locks the system settings. If there is no
password set, a prompt will request one be entered.
UNIT CONFIG > CONSOLE LOCK> ENABLE><Enter and hold>
If a User
’
s Password has been set and enabled, the unit does not allow
changing system settings, such as port settings and unit configuration, unless
the correct password is keyed in thereby unlocking the Mini-Console.
Unlock the Console
Once the console is locked, a password will be asked when the menu item
UNIT CONFIG is selected.