18
2-1-3-1. Cabling Requirements for TP Ports
⇒
For Fast Ethernet TP network connection
The grade of the cable must be Cat. 5 or Cat. 5e with a maximum length of
100 meters.
⇒
Gigabit Ethernet TP network connection
The grade of the cable must be Cat. 5 or Cat. 5e with a maximum length of
100 meters. Cat. 5e is recommended.
2-1-3-2. Cabling Requirements for 1000SX/LX SFP Module
It is more complex and comprehensive contrast to TP cabling in the fiber
media. Basically, there are two categories of fiber, multi mode (MM) and single
mode (SM). The later is categorized into several classes by the distance it supports.
They are SX, LX, LHX, XD, and ZX. From the viewpoint of connector type, there
mainly are LC and BiDi-SC.
Gigabit Fiber with multi-mode LC SFP module
Gigabit Fiber with single-mode LC SFP module
The following table lists the types of fiber that we support and those else not
listed here are available upon request.
IEEE 802.3z
Gigabit Ethernet
1000SX 850nm
Multi-mode Fiber Cable and Modal Bandwidth
Multi-mode 62.5/125
µ
m
Multi-mode 50/125
µ
m
Modal
Bandwidth
Distance
Modal
Bandwidth
Distance
160MHz-Km
220m
400MHz-Km
500m
200MHz-Km
275m
500MHz-Km
550m
1000Base-
LX/LHX/XD/ZX
GVT-0301 10Km, GVT-0302 80 Km
Single-mode Fiber 9/125
µ
m
Single-mode transceiver 1310nm 10Km
Single-mode transceiver 1550nm 70Km
Table2-1
Содержание FGP-1072
Страница 1: ...i FGP 1072 8FE PoE 2GE Combo SFP L2 Managed Switch User Manual Ver 1 00 1206...
Страница 32: ...32 Fig 2 15 Office Network Connection Fig 2 14 Peer to peer Network Connection...
Страница 45: ...45 Fig 3 5...
Страница 133: ...133 Same as mentioned in Port Config Restricted Tcn Same as mentioned in Port Config...
Страница 173: ...173 Fig 3 85 Fig 3 86 Fig 3 87...
Страница 175: ...175 Fig 3 91 Rate Meter To set rate meter function with the bandwidth parameter The range is 64 to 1024000kbps Fig 3 92...
Страница 193: ...193 Managed Switch FGP 1072 Login admin Password FGP 1072 Fig 4 1...