Electrical
3
S023074
PA1
2020-05-12
69
4. Test the new riv-nut/stud to confirm the resistance is less than 0.003 ohms (Refer to step 2).
Do not use lock nuts, nyloc nuts or spring washers on high current terminals. Use self locking
hexagonal crimp nuts made from low resistance materials on high current terminals. This type of
nut has a large surface area and a deformed female thread that locks to male threaded
components.
Do not install more than two ring terminals on one stud. The highest current draw terminal must
be connected nearest to the stud.
Windshield Wipers
WARNING
Do not make changes to the windscreen wiper system.
For more information on the windscreen wipers refer to the operators manual or the workshop
manual.
NOTE
For additional information or technical support contact [email protected].