Troubleshooting
Leuze electronic GmbH + Co. KG
MSI-TR1B / MSI-TR2B
29
11
Troubleshooting
11.1 What to do in case of failure?
After switching on the safety relay, display elements (LEDs, see chapter 3.2 "Display elements") assist in
checking the proper function and troubleshooting.
In case of error, you can determine the error from the LED displays. With the error message you can deter
-
mine the cause of the error and initiate measures to rectify it.
11.2 Operating indicators of the LEDs
If it was possible to rectify a detected error, perform an "MSI restart" (24 V on terminal 21) or briefly dis
-
connect the MSI-TRxB from the voltage supply.
NOTE
If the safety relay indicates a fault, it may be defective.
Switch off the machine and leave it switched off.
Analyze and eliminate the cause of the fault (see chapter 11.2 "Operating indicators of the
If you are unable to rectify the fault, contact the Leuze branch responsible for you or call the
Leuze hotline.
LED
State
Cause
Measure
EDM
Flashing
Fault in the EDM wiring Check the wiring of the
connected contactors.
Sensor
Flashing
Fault in the wiring of the
protective sensors
Check the wiring of the
protective sensors.
Sensor, EDM and start
Simultaneous flashing
Internal device error
In the event of an unsuc
-
cessful restart, contact
customer service.