background image

Technical data

Leuze electronic GmbH + Co. KG

MSI-RM2B

21

Table 13.3:

Time behavior

13.2 Interference emission

The device corresponds to CISPR 11/ EN 55011 Group 1 and Class B.
Groups

• Group 1: All devices that do not belong to Group 2 (lab equipment, devices for industrial process 

measurement and control)

• Group 2: All devices that intentionally generate HF energy for material processing / modification 

(microwave and induction ovens, electric welding equipment)

Classes

• Class A: Industrial systems in which the 230V supply network is provided by means of a separate 

transformer (from medium voltage)

• Class B: Commercial, industrial locations and residential areas that are supplied by the public 230V 

network (low-voltage network) or are connected to it

13.3 Dimensions

Figure 13.1: Dimensions MSI-RM2B-01

Pickup delay

20 ms

Regression delay, reaction time

10 ms

99.0

114.1

17.5

111.5

Содержание MSI-RM2B

Страница 1: ...MSI RM2B Safety Relays Original operating instructions EN 2022 03 29 50124437 We reserve the right to make technical changes...

Страница 2: ...2022 Leuze electronic GmbH Co KG In der Braike 1 D 73277 Owen Germany Phone 49 7021 573 0 Fax 49 7021 573 199 http www leuze com info leuze de...

Страница 3: ...6 Mounting 10 7 Electrical connection 11 7 1 Terminal assignments 11 7 2 Circuit diagram examples 12 8 Starting up the device 13 8 1 Switching on 13 9 Testing 14 9 1 Before the initial start up and fo...

Страница 4: ...njuries Indicates dangers that may result in minor injury if the measures for danger avoid ance are not followed WARNING Signal word for serious injury Indicates dangers that may result in severe or f...

Страница 5: ...quipment directive 2009 104 EC OSHA 1910 Subpart 0 Safety regulations Accident prevention regulations and safety rules Ordinance on Industrial Safety and Health and employment protection act Product s...

Страница 6: ...nipulating the safety relay also voids all warranty claims against the manufacturer of the safety relay The safety relay must be tested regularly by a competent person see chapter 9 Testing The safety...

Страница 7: ...rating personnel Maintaining the safe operation of the machine Adhering to all regulations and directives for labor protection and safety at work Regular testing by competent persons 2 4 Exemption of...

Страница 8: ...ntial circuit for safe protective devices with 2 OSSDs and contactor monitoring EDM Figure 3 3 Internal circuit diagram of the MSI RM2B Figure 3 1 MSI RM2B with screw terminals Figure 3 2 MSI RM2B wit...

Страница 9: ...s LED displays K1 and K2 Operating voltage 24 V DC Housing width 17 5 mm Removable connection terminal blocks screw terminals spring cage terminals 3 2 Display elements The display elements of the saf...

Страница 10: ...The MSI RM2B safety relay converts the electronic safety related switching outputs of safety sensors or safety relays into potential free positive guided contacts with signaling path It can be integra...

Страница 11: ...Applications Leuze electronic GmbH Co KG MSI RM2B 9 5 Applications Figure 5 1 Guarding a paternoster shelf with MLC safety light curtain and MSI RM2B relay module...

Страница 12: ...ace on the DIN rail Snap the safety relay onto the DIN rail The safety relay can be connected to the safety sensors WARNING Improper mounting may result in serious injury The protective function of th...

Страница 13: ...ious functions are connected DANGER Risk of death by electric shock Depending on external wiring dangerous voltages may be present at the switching outputs During all work at the electrical system or...

Страница 14: ...ntact 1 OUT Y1 External device monitoring circuit EDM n c n c Y2 External device monitoring circuit EDM A2 0 V B1 Sensor input channel 1 24 V B3 Sensor input channel 2 24 V 14 Relay contact 1 IN NO 21...

Страница 15: ...ments for the supply voltage power supply unit Safe mains separation is ensured acc to EN IEC 60742 Changes and interruptions of the supply voltage are handled acc to IEC 61496 1 2020 The start restar...

Страница 16: ...their respective tasks The training is the responsibility of the operating company Check whether the safety relay was correctly selected acc to the locally applicable regulations and directives Check...

Страница 17: ...s the required safety distance protective field to the next point of operation main tained Are all points of operation of the machine accessible only through the protective field Are all additional pr...

Страница 18: ...ester authorized operating personnel or instructed person Table 9 2 Check list daily or at change of shift WARNING Unpredictable machine behavior during the test may result in serious injury Make cert...

Страница 19: ...Maintenance Leuze electronic GmbH Co KG MSI RM2B 17 10 Maintenance The safety relay is maintenance free...

Страница 20: ...Disposing Leuze electronic GmbH Co KG MSI RM2B 18 11 Disposing For disposal observe the applicable national regulations regarding electronic components...

Страница 21: ...together with a description Please register the merchandise concerned Simply register return of the merchandise on our website www leuze com under Contact Support Repair Service Returns To ensure quic...

Страница 22: ...hangeovers 1 NC contact AgNi10 5 mm Au Switching capacity of the contacts acc to EN IEC 60947 5 1 Y1 and Y2 DC 13 NC contact 24 V 2 A 11 12 14 21 22 24 DC 13 NO contact 24 V 4 A NC contact 24 V 2 A 11...

Страница 23: ...ally generate HF energy for material processing modification microwave and induction ovens electric welding equipment Classes Class A Industrial systems in which the 230V supply network is provided by...

Страница 24: ...Technical data Leuze electronic GmbH Co KG MSI RM2B 22 Figure 13 2 Dimensions MSI RM2B 02 111 114 1 17 5 111 5...

Страница 25: ...ze electronic GmbH Co KG MSI RM2B 23 14 Order guide Table 14 1 MSI RM2H safety relays Part no Article Description 547954 MSI RM2B 01 Safety relay screw terminals 547955 MSI RM2B 02 Safety relay spring...

Отзывы: