Electrical connection
Leuze electronic
LES 36
51
TNT
35/7-2
4
V
Figure 6.8:
Response of analog output LES
Possible value ranges depending on set analog output value:
Note!
Valid Z-values are output 10mm above and beyond the max. measurement range:
190 … 810mm.
LES 36…
LES 36HI…
X coordinate
-300 … +300mm
-70 … +70mm
Z-coordinate
+200 … +800mm
+200 … +800mm
Height difference
0 … 600mm
0 … 400mm
Width
0 … 600mm
0 … 140mm