Commissioning steps at a glance
Leuze electronic
BPS 34
9
TNT 35/7-24V
Notice!
During mounting, the following angles of inclination must be taken into account in the vertical
axis:
10 ° for a tape height of 47 mm,
7 ° for a tape height of 30 mm and
5 ° for a tape height of 25 mm; the working range of the reading field curve must also be tak-
en into account.
Attention!
For the position calculation, the scanning beam of the BPS 34 must be incident on the bar-
code tape without interruption. Ensure that the scanning beam is always incident on the bar-
code tape when the system is moving.
Connecting the voltage supply and PROFIBUS
The BPS 34, in combination with an MS 34 103 or MS 34 105, is connected via M12
connectors.
Connecting the voltage supply
The voltage supply is connected via the
PWR IN
M 12 connection.
Figure 3.2:
BPS 34 with MS 34 103/MS 34 105 - Connection PWR IN
➁
Socket
(A-coded)
Socket
(A-coded)
Socket
(B-coded)
Plug
(B-coded)
Plug
(A-coded)
PWR IN
SWIN
SWOUT
3
2
1
4
GND
VIN
PE
SW IN/OUT
1
2
3
4
VOUT
PE
SWIN
SWOUT
GND
DP IN
GND 3
2
1
4
PE
A (N)
B (P)
VCC
DP OUT
VCC 1
2
3
4
A (N)
B (P)
GND
PE
1
2
3
4
MSD
5
6
7
/SERV
VIN
TXD
RXD
SCL
SDA
GND
/INT