Menu structure AMS 300
i
Level 1
Level 2
Level 3
Level 4
Level 5
Selection/configuration option
Detailed infor
-
mation on
: Selection
: Selection
: Selection
: Selection
: Selection
: Selection
: Back
: Back
: Back
: Back
: Activate
: Back
Device information
Network information
Status and mea
-
surement data
Parameter
Parameter handling
Parameter enable
ON/OFF
Password
Activate password
ON/OFF
Password entry
For setting a four-digit numerical password
Parameters to default
All parameters are reset to their factory settings
RS 422/RS 232
Selection
RS 422/RS 232
Baud rate
19.2 kbit/s / 38.4 kbit/s / 57.6 kbit/s / 115.2 kbit/s
Data format
… 8,n,1 / … 8,e,1 / … 8,o,1
Output cycle
Value input:
Position resolution
0.01mm / 0.1mm / 1mm / 10mm / free resolution
Velocity resolution
1mm/s / 10mm/s / 100mm/s
Position value
Unit
Metric/Inch
Counting direction
Positive/Negative
Offset
Value input:
Preset
Value input
Error delay
ON/OFF
Position value in the case of
failure
Last valid value / zero
Free resolution value
5 … 50000
I/O
I/O 1
Port configuration
Input/Output
Switching input
Function
No function/teach preset/laser ON/OFF
Activation
Low active/High active
Switching output
Function
Pos. limit value 1 / Pos. limit value 2 / Velocity / Intensity (ATT) / Temp. (TMP) /
Laser (LSR) / Plausibility (PLB) / Hardware (ERR)
Activation
Low active/High active
I/O 2
Port configuration
Input/Output
Switching input
Function
No function/teach preset/laser ON/OFF
Activation
Low active/High active
Switching output
Function
Pos. limit value 1 / Pos. limit value 2 / Velocity / Intensity (ATT) / Temp. (TMP) /
Laser (LSR) / Plausibility (PLB) / Hardware (ERR)
Activation
Low active/High active
Limit values
Upper pos. limit 1
Activation
ON/OFF
Limit value input
Value input in mm or inch/100
Lower pos. limit 1
Activation
ON/OFF
ESC
ESC
ESC
ESC
ESC