PROFINET interface
Leuze electronic GmbH + Co. KG
AMS 348
i
SSI
83
TNT
35/7-2
4V
9.9.3.6 Module 6: Status and control
PROFINET module identifier
Module ID
1006
Submodule ID
1
Description
The module signals various status information of the AMS 348
i
. The laser can be controlled
via the master's output data.
Parameter
None
Input data
Input data
Description
Rel.
addr
.
Data
type
Value
Default Unit
CR to
module
Metr. Inch
Laser
status
Signals the laser status.
1.0 Bit
0: Laser ON
1: Laser OFF
–
–
–
Preset
status
State of the preset value.
1.1 Bit
0: Preset not active
1: Preset active
–
–
–
Preset
teach
This bit toggles at each teach
event of a preset value.
1.2 Bit
0 or 1
–
–
–
Reserve
1.3 Bit
–
–
–
Intensity
(ATT)
If the intensity of the received sig
-
nal is less than the warning
threshold, the status bit is set.
1.4 Bit
0: OK
1: Warning
–
–
–
Tempera
-
ture (TMP)
If the internal device temperature
exceeds or drops below the set
limit value, the status bit is set.
1.5 Bit
0: OK
1: Temperature above/
below limit
–
–
–
Laser (LSR) Laser prefailure message.
1.6 Bit
0: OK
1: Laser warning
–
–
–
Plausibility
(PLB)
If implausible measurement val
-
ues are diagnosed, the status bit
is set.
1.7 Bit
0: OK
1: Implausible mea
-
surement values
–
–
–
Hardware
(ERR)
If a hardware error is diagnosed,
the status bit is set.
0.0 Bit
0: OK
1: Hardware error
–
–
–
Lower posi
-
tion limit
value 1
Signals that the value is less than
lower limit value 1.
0.4 Bit
0: OK
1: Value less than limit
–
–
–
Upper posi
-
tion limit
value 1
Signals that the value is greater
than upper limit value 1.
0.5 Bit
0: OK
1: Value greater than
limit
–
–
–
~