Installation
Leuze electronic GmbH + Co. KG
BPS 37
18
Mounting example BPS 37
Figure 6.1: Mounting example BPS 37
Mounting of MA
You can mount all connection units individually through the holes located on the mounting plate (see
Figure 5.1).
Subsequently, connect the BPS 37 with the connection unit via the respective cable (see Chapter 5.1.3).
6.2.1 Device arrangement
Selecting a mounting location
In order to select the right mounting location, several factors must be considered:
• The scanning range determined from the scanning curve must be adhered to at all areas at which a
position determination is to be made
• The BPS should be mounted inclined by 10° in the vertical axis towards the bar code tape to ensure
that the read results are reliably obtained even if the bar code tape is soiled.
BT 56 mounting
device
NOTE
The best functionality is obtained when:
• The BPS is guided parallel to the tape
• The permitted working range is not exited
NOTE
On the BPS 37, the beam is not emitted perpendicular to the housing cover, but with an angle
of 10° towards the top. This angle is intended to prevent total reflection on the bar code tape.
2
0 8
0 8
2
0
0028
0028
002816
0 8
02
0028
0
00
04
08
12
20
24
10°
*
*
*
*
*
*
*