IO-Link interface
Sensors in the PRK3C…/L… variant have a dual-channel architecture. The IO-
Link interface is available in accordance with specification 1.1.2 (July 2013) on pin
4 (OUT 1). You can easily, quickly and economically configure the devices via the
IO-Link interface. Furthermore, the sensor transmits the process data via the IO-
Link interface and makes diagnostic information available through it.
Parallel to the IO-Link communication, the sensor can output the continuous
switching signal for object detection on OUT 2. The IO-Link communication does
not interrupt this signal.
NOTICE
In the
Sensor Studio configuration software, the following applies with
regard to the designations: Q1 = OUT 1, Q2 = OUT 2.
The sensors offer no data retention and no ISDU support. The device can only be
identified via VendorID and DeviceID.
IO-Link identification
VendorID dec/hex
DeviceID dec/hex
Device
338/0x152
2119/0x000847
PRK3CL1.A3/LP
IO-Link process data
Device output data
Data bit
Assignment
Meaning
0
Switching output Q1
(OUT 1)
0 = inactive, 1 = active
1
Warning output autoCon-
trol
0 = no warning, 1 = warning
2
Sensor operation
0 = off, 1 = on
Sensor operation off when detection is
not possible (e.g during the teach event).
3
Not assigned
Free
4
Not assigned
Free
5
Not assigned
Free
6
Not assigned
Free
7
Not assigned
Free
7
EN