Leuze electronic ODSL 96B Скачать руководство пользователя страница 4

ODSL 96B M/… - 05

2013/01

Teach-in of switching outputs, analog characteristic output curve and Preset

Notice!

If you have changed the factory setting for teaching under Input Mode, activate on the OLED display the menu item 

Input

 -> 

Input Mode

 -> 

Teach

.

To teach, proceed as follows:

1.

Position measurement object at the desired measurement distance. 

2.

The respective teach function is activated on the teach input for the duration of a level change 

T

 (see graphical representation). 

The level conditions describe the levels with menu setting 

Input

 -> 

Input Mode

 -> 

Input polarity

 -> 

Active High +24V

 (factory 

setting).

Notice!

If the inactive level is continuously applied on the teach input, the teach input is locked.

For menu setting 

Input

 -> 

Input Mode

 -> 

Input polarity

 -> 

Active Low +0V

, inverted input signals are used during 

teaching.

Preset Teach-In

On the OLED display, activate for this purpose menu item 

Input

 -> 

Input Mode

 -> 

Preset

.

The preset teach occurs in a manner analogous to that for the teach-in for switching output Q1.

Working safely

Attention Laser Radiation!

The optical distance sensors ODSL 96B operate with a red light laser of class 2 acc. to EN 60825-1. If you look 
into the beam path over a longer time period, the retina of your eye may be damaged! 

Never look directly into the beam path! Do not point the laser beam of the ODSL 96B at persons!

When mounting and aligning the ODSL 96B take care to avoid reflections of the laser beam off reflective 
surfaces! 

The use of operating and adjusting devices other than those specified in the technical description, carrying out 
of differing procedures, or improper use of the optical laser distance sensor may lead to dangerous exposure to 
radiation! 

The use of optical instruments or devices in combination with the device increases the danger of eye damage!

Adhere to the applicable legal and local regulations regarding protection from laser beams acc. to EN 60825-1 in 
its latest version.

The ODSL 96B uses a laser diode with low power in the visible red light range with an emitted wavelength of 
about 658nm. 

The glass optics cover is the only opening through which the laser radiation can escape from the device. The 
housing of the ODSL 96B is sealed and has no parts that need to be adjusted or maintained by the user. The 
device must not be tampered with and must not be changed in any way! The destruction of the seal voids the 
warranty!

Notice!

It is important that you attach the sticky labels supplied to the device (notice signs and laser emission symbol)! 
If the signs would be covered due to the installation situation of the ODSL 96B, attach them close to the 
ODSL 96B such that reading the notices cannot lead to looking into the laser beam!

Teach function

Duration T

Switching output Q1

20 … 80ms

Distance value for start of measurement range =
1V or 4mA at analog output

220 … 280ms

Distance value for end of measurement range =
10V or 20mA at analog output

320 … 380ms

Inactive Low 0V

T

t

Active High +24V

ODSL 96B

Содержание ODSL 96B

Страница 1: ... value is indicated in mm on OLED display Measurement range and mode adjustable 0 3 10m 18 30 V DC Accessories available separately Mounting systems Cable with M12 connector K D Configuration software IEC 60947 IEC 60947 IP IP 69K 69K IP IP 67 67 Dimensioned drawing A Green indicator diode B Indicator diode yellow C Transmitter D Receiver E Optical axis F Device plug M12x1 G Countersinking for SK ...

Страница 2: ...t bit 8 data bits 1 stop bit no parity Transmission protocol 14 bit 16 bit ASCII Remote Control Indicators Teach in on GND Green LED continuous light ready off no voltage Yellow LED continuous light object within range switching output off object out of range switching output Mechanical data Metal housing Housing diecast zinc Optics cover glass Weight 380g Connection type M12 connector Environment...

Страница 3: ...unt Notice The measurement value display on the OLED display can be used to assess the efficiency of the selected measurement mode and measurement filter in the application The update rate of the OLED display is always 2Hz The ODS 96B configuration software provides identical functionality Factory setting of measurement mode On delivery the sensor is preset so that measurement values with the maxi...

Страница 4: ...e care to avoid reflections of the laser beam off reflective surfaces The use of operating and adjusting devices other than those specified in the technical description carrying out of differing procedures or improper use of the optical laser distance sensor may lead to dangerous exposure to radiation The use of optical instruments or devices in combination with the device increases the danger of ...

Отзывы: