ODSL 8/V66-45-S12 - 06

2018/12

ODSL 8/C66-45-S12 - 06

Specifications

Optical data 

Measurement range 

1)

1) Luminosity coefficient 6% … 90%, at 20°C, measurement object 

20x20mm²

25 … 45mm

Resolution 

2)

2) Minimum and maximum value depend on measurement distance and configuration of the analog output

0.03mm

Light source

laser

Laser class

2 acc. to IEC 60825-1:2007

Wavelength

650nm (visible red light)

Max. output power

<1.2 mW 

Pulse duration

4ms

Light spot

Ø 1mm at 45mm 

Error limits (relative to measurement distance)

Absolute measurement accuracy 

1)

± 1,5% 

Repeatability 

3)

3) Same object, identical environmental conditions, measurement object 

20x20mm²

± 0.2% 

B/W detection thresh. (6 … 90% rem.)

1,5%

Temperature drift

≤ 

0.2%/°C

Timing

Measurement time

2 … 7ms

Response time 

20ms

Delay before start-up 

300ms

Electrical data

Operating voltage U

B

 

18 … 30VDC (incl. residual ripple)

Residual ripple

15% of U

B

 

Open-circuit current

50mA

Switching output/function

4)

4) The push-pull switching outputs must not be connected in parallel

2 push-pull switching outputs
pin 2: Q2, PNP light switching, NPN dark switching 
pin 4: Q1, PNP light switching, NPN dark switching

Signal voltage high/low

(U

B

-2 V)/

2V

Analog output

voltage 1 … 10V, R

L

2k

Ω

 / current 4 … 20mA, R

L

<

500

Ω

Indicators 

Green LED continuous light

ready

flashing (no teach)

fault, teach values were not applied

off

no voltage

Yellow LED continuous light

object within teach-in measurement distance (output Q1 

5)

)

5) No display for output Q2

flashing (no teach)

teach values were not applied

off

object outside teach-in measurement distance (output Q1 

6)

)

Mechanical data 

Housing metal
Optics cover 

glass

Weight 70g 
Connection type 

M12 connector, 5-pin, turning

Environmental data

Ambient temp. (operation/storage)

-40°C … +50°C/-40°C … +70°C

Protective circuit 

6)

6) 2=polarity reversal protection, 3=short circuit protection for all outputs

2, 3

VDE safety class 

7)

7) Rating voltage 250VAC

II, all-insulated 

Protection class 

8)

8) In end position of the turning connector (turning connector engaged)

IP 67, IP 69K 

9)

9) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,

acids and bases are not part of the test

Environmentally tested acc. to

ECOLAB

Standards applied 

IEC 60947-5-2

Certifications

UL 508, CSA C22.2 No.14

Order guide

Designation

Part no.

With M12 connector
and voltage output

ODSL 8/V66-45-S12

50108363

and current output

ODSL 8/C66-45-S12

50108364

Diagrams

Characteristic curve of switching 
outputs:

A

Hysteresis

B

Switching point Q1 (teach point)

C

Switching point Q2 (teach point)

D

Measurement distance

ODSL 8

Remarks

Measurement time 
depends on the reflectivity 
of the measurement 
object and on the mea-
surement mode.

Operate in accordance with
intended use!

This product is not a safety sensor 
and is not intended as personnel 
protection.

The product may only be put into 
operation by competent persons.

Only use the product in accor-
dance with the intended use.

Содержание ODSL 8 Series

Страница 1: ...ng connector Easy alignment through visible red light 25 45mm IP IP 69K 69K IP IP 67 67 Accessories available separately Mounting systems Cables with M12 connector KD Control guard Dimensioned drawing A Receiver B Transmitter C Optical axis D Turning connector 90 rot angle E Yellow green LED F Operational control rotary switch G Reference edge for the measurement cover glass Electrical connection ...

Страница 2: ...ect within teach in measurement distance output Q1 5 5 No display for output Q2 flashing no teach teach values were not applied off object outside teach in measurement distance output Q1 6 Mechanical data Housing metal Optics cover glass Weight 70g Connection type M12 connector 5 pin turning Environmental data Ambient temp operation storage 40 C 50 C 40 C 70 C Protective circuit 6 6 2 polarity rev...

Страница 3: ...n using the device in the US use the stick on label with the Complies with 21 CFR 1040 10 notice Affix the laser information and warning signs near the device if no signs are attached to the device e g because the device is too small or if the attached laser information and warning signs are concealed due to the installation position Affix the laser information and warning signs so that they are l...

Страница 4: ...ed F Measurement distance Preferred movement of the objects Preferred mounting in connection to objects with structured surface View through a chase If the ODSL 8 has to be installed behind a cover the chase has to have at least the size of the optical glass cover Otherwise a correct measurement is not possible or can not be guaranteed Alignment to measurement objects with reflecting surfaces If t...

Страница 5: ...n Reset 10V 20mA analogue output at 45mm 1 Position measurement object just beyond end of measurement range 45mm 2 Position rotary switch on High Wait for optical confirmation by flashing of the LEDs 3 For teaching position rotary switch onto Run Wait for optical confirmation by end of flashing signal green LED on Error messages Continuously flashing LEDs in switch position Run signal an unsuccess...

Страница 6: ...ODSL 8 V66 45 S12 06 2018 12 ODSL 8 C66 45 S12 06 ODSL 8 ...

Отзывы: