![Leuze electronic ODSL 8 Series Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/leuze-electronic/odsl-8-series/odsl-8-series_quick-start-manual_1883880002.webp)
2018/12
Specifications
Optical data
Measurement range
1)
1) Luminosity coefficient 6% … 90%, at 20°C, measurement object
≥
20x20mm²
25 … 45mm
Resolution
2)
2) Minimum and maximum value depend on measurement distance and configuration of the analog output
0.03mm
Light source
laser
Laser class
2 acc. to IEC 60825-1:2007
Wavelength
650nm (visible red light)
Max. output power
<1.2 mW
Pulse duration
4ms
Light spot
Ø 1mm at 45mm
Error limits (relative to measurement distance)
Absolute measurement accuracy
1)
± 1,5%
Repeatability
3)
3) Same object, identical environmental conditions, measurement object
≥
20x20mm²
± 0.2%
B/W detection thresh. (6 … 90% rem.)
≤
1,5%
Temperature drift
≤
0.2%/°C
Timing
Measurement time
2 … 7ms
Response time
≤
20ms
Delay before start-up
≤
300ms
Electrical data
Operating voltage U
B
18 … 30VDC (incl. residual ripple)
Residual ripple
≤
15% of U
B
Open-circuit current
≤
50mA
Switching output/function
4)
4) The push-pull switching outputs must not be connected in parallel
2 push-pull switching outputs
pin 2: Q2, PNP light switching, NPN dark switching
pin 4: Q1, PNP light switching, NPN dark switching
Signal voltage high/low
≥
(U
B
-2 V)/
≤
2V
Analog output
voltage 1 … 10V, R
L
≥
2k
Ω
/ current 4 … 20mA, R
L
<
500
Ω
Indicators
Green LED continuous light
ready
flashing (no teach)
fault, teach values were not applied
off
no voltage
Yellow LED continuous light
object within teach-in measurement distance (output Q1
5)
)
5) No display for output Q2
flashing (no teach)
teach values were not applied
off
object outside teach-in measurement distance (output Q1
6)
)
Mechanical data
Housing metal
Optics cover
glass
Weight 70g
Connection type
M12 connector, 5-pin, turning
Environmental data
Ambient temp. (operation/storage)
-40°C … +50°C/-40°C … +70°C
Protective circuit
6)
6) 2=polarity reversal protection, 3=short circuit protection for all outputs
2, 3
VDE safety class
7)
7) Rating voltage 250VAC
II, all-insulated
Protection class
8)
8) In end position of the turning connector (turning connector engaged)
IP 67, IP 69K
9)
9) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,
acids and bases are not part of the test
Environmentally tested acc. to
ECOLAB
Standards applied
IEC 60947-5-2
Certifications
UL 508, CSA C22.2 No.14
Order guide
Designation
Part no.
With M12 connector
and voltage output
ODSL 8/V66-45-S12
50108363
and current output
ODSL 8/C66-45-S12
50108364
Diagrams
Characteristic curve of switching
outputs:
A
Hysteresis
B
Switching point Q1 (teach point)
C
Switching point Q2 (teach point)
D
Measurement distance
ODSL 8
Remarks
Measurement time
depends on the reflectivity
of the measurement
object and on the mea-
surement mode.
Operate in accordance with
intended use!
This product is not a safety sensor
and is not intended as personnel
protection.
The product may only be put into
operation by competent persons.
Only use the product in accor-
dance with the intended use.