Mounting
Leuze electronic
MLC 520S
22
6.1.4
Preventing mutual interference between adjacent devices
If a receiver is located in the beam path of an adjacent transmitter, optical crosstalk, and thus erroneous
switching and failure of the protective function, may result.
3
1
4
2
Fig. 6.4:
Optical crosstalk between adjacent safety sensors (transmitter 1 influences receiver 2) due to incorrect
mounting
1
Transmitter 1
2
Receiver 1
3
Transmitter 2
4
Receiver 2
NOTICE
Possible impairment of the availability due to systems mounted close to each other!
The transmitter of one system can influence the receiver of the other system.
Ä
Prevent optical crosstalk between adjacent devices.
Ä
Mount adjacent devices with a shield between them or install a dividing wall to prevent mutual interference.
Ä
Mount the adjacent devices opposite from one another to prevent mutual interference.
3
1
4
2
Fig. 6.5:
Opposite mounting
1
Receiver 1
2
Transmitter 1
3
Transmitter 2
4
Receiver 2