Table 13.1:
Safety-relevant technical data
Table 13.2:
Connection
Actuator, external
Magnetically coded, compatible with respective sensor
series
Safe switching distances and off distance if markings are aligned:
Sao = assured cut-in distance
OFF = cut-out point
Sar = assured cut-out distance
388 series: Sao (ON), (OFF), Sar
< 6 mm, > 13 mm, > 30 mm
336 series: Sao (ON), (OFF), Sar
< 3 mm, > 8 mm, > 11 mm
330 series: Sao (ON), (OFF), Sar
< 6 mm, > 12 mm, > 14 mm
Switching tolerance (without ferromagnetic
materials in immediate vicinity)
± 1 mm
Certification
TÜV-SÜD, cULus
Contact type
Reed contacts (magnetically sensitive)
Contact allocation
1NC/1NO
Mechanical life time
10 million switching cycles
Max. switching voltage
27 V AC/DC
Switched current Ie max.
0.5 A
Short circuit protection
By means of MSI-MC310 Safety Relay
Installation point
Arbitrary, provided housing markings are aligned
Min. distance to other magnetic sensors
50 mm
Approach actuation directions
In longitudinal axis, left and right
In vertical axis, up and down
In depth, to and from sensor
Min. approach speed of actuator towards sen
-
sor
50 mm/s
Response time
3 ms
Number of connection cable infeeds
1 (connection cable or M8 plug)
Connection type
Connection cable with wire-end sleeves or M8 plug,
each molded to housing
Conductor cross-section (stranded)
4 x 0.35 mm
²
(connection cable)