Fast commissioning / operating principle
Leuze electronic
MA 258
i
21
TNT
35/7-2
4
V
Notice!
Since the combination of Produced/Consumed data contains 2 bytes for the control and
status bytes, the actual user data length is always 2 bytes smaller than specified in the
selected combination.
E.g., when using the combination with 12 bytes In/12 bytes Out, there are effectively 10 bytes
available for user data on the Leuze device after subtracting the 2 bytes for status and control
bytes.
Recommendation
A combination with 4 bytes of output data length is sufficient for most output data.
A longer length is needed, for example, if a BCL bar code scanner is to be configured by
means of PT-sequences, or an RFID transponder is to be described. In these cases, larger
combinations are usually advisable.
Select the appropriate combination and transmit the settings to the device.
Figure 3.7:
MA settings in the controller tags