Application example 1: web edge measurement
In the following example, the right edge position of web material is to be ascertained. Edge
analysis window EAW1 is positioned in the measurement range so that the web material is
located within the window.
The ascertained position of the right edge is -9.6mm (column
Edge1
->
Right Most
-> line
X
).
The distance from the edge to the sensor is 366.6mm (column
Edge1
->
Right Most
->line
Z
).
Figure 9.7: