Integration of the LES 36/PB in the PROFIBUS
Leuze electronic
Technical description LES
121
TNT
35/7-2
4
V
Measurement value 1 in Edge Analysis Window EAW1
This is a signed 16-bit value (bytes
wEdgeAW1Data1
HighByte and
wEdgeAW1Data1
LowByte). Measurement value 1 of Edge Analysis Window EAW1 (= Profibus Inputs 1) is
output in the value (for information on configuration, see "Profibus Inputs 1 , Profibus Inputs 2"
on page 83).
The
value range is -32768 … +32767
. The measurement value has
units of 0.1mm
, i.e., a
measurement value of +1263 corresponds to 126.3mm.
11.6.2
Module M2
The maximum measurement rate of 100Hz is ensured if this module is set.
Notice!
Module M2 contains the input data from module M1. Only the additional input data are
described in this section.
Measurement value 2 in Edge Analysis Window EAW1 (wEdgeAW1Data2)
Measurement value 1 in Edge Analysis Window EAW2 (wEdgeAW2Data1)
Measurement value 2 in Edge Analysis Window EAW2 (wEdgeAW2Data2)
Measurement value 1 in Edge Analysis Window EAW3 (wEdgeAW3Data1)
These are signed, 16-bit measurement values (for information on configuration, see
"Profibus Inputs 1 , Profibus Inputs 2" on page 83).
Notice!
Description see "Measurement value 1 in Edge Analysis Window EAW1" on page 121.
Byte
Bit
Designation
Meaning
wEdgeA
W1Data1
(High-Byte)
7
sign
Sign
6
OP_b14
Measurement value
5
OP_b13
Measurement value
4
OP_b12
Measurement value
3
OP_b11
Measurement value
2
OP_b10
Measurement value
1
OP_b9
Measurement value
0
OP_b8
Measurement value
wEdgeA
W
1
D
a
ta
1
(Lo
w
-Byte)
7
OP_b7
Measurement value
6
OP_b6
Measurement value
5
OP_b5
Measurement value
4
OP_b4
Measurement value
3
OP_b3
Measurement value
2
OP_b2
Measurement value
1
OP_b1
Measurement value
0
OP_b0
Measurement value
Table 11.6:
Input data bytes
wEdgeAW1Data1
(high and low byte)